background image

                                               

                                                       

Bi1248

1200

 

User

 

Manual

 

 

   

                                                                     

6

5.

 

Installation

     

     

 

For

 

the

 

user

 

operation

 

safety,

 

cut

 

off

 

the

 

power

 

before

 

installation.

 

 

 

Please

 

double

 

check

 

that

 

the

 

installed

 

battery

 

voltage

 

is

 

48Vdc

 

 

5.1

 

Installation

 

recommendations

 

and

 

operations

   

 

It

 

is

 

necessary

 

to

 

turn

 

off

 

the

 

power

 

switch

 

or

 

external

 

control

 

signal

 

to

 

prevent

 

Bi1248

1200

 

from

 

working

 

due

 

to,

 

which

 

may

 

cause

 

sparkling

 

during

 

the

 

wiring

 

process.

 

 

Please

 

select

 

the

 

appropriate

 

location

 

with

 

adequate

 

ventilation

 

to

 

install

 

Bi1248

1200,

 

and

 

fix

 

it

 

with

 

M5

 

screws.

 

 

In

 

order

 

to

 

ensure

 

the

 

ventilation,

 

please

 

assure

 

minimum

 

10cm

 

without

 

obstruction

 

at

 

both

 

ends.

 

And,

 

minimum

 

5cm

 

at

 

left

 

and

 

right

 

side.

 

 

 

170

291.6

4-

?

5

5cm

5cm

10cm

10cm

 

 

 

Back 

Left 

Right

Front 

Summary of Contents for Bi1248-1200

Page 1: ...Bi1248 1200 User Manual TBB Power Co Ltd Bi directional Converter Charger Bi1248 1200 User Manual Version A1 0 Date Dec 2019...

Page 2: ...0 User Manual TBB Power Co Ltd WARNING FIRE HAZARD SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON COMBUS TABLE SURFACE ONLY CAUTION THE DC AND AC BREAKER MUST HAVE BEEN TURNED OFF BEFORE SERVICING MAD...

Page 3: ...or choosing our products and this manual were suitable for DC DC Bi directional Converter Bi1248 1200 This chapter contains important safety and operation instructions Read and keep this User Guide we...

Page 4: ...nstallation Configuration 5 4 1 Unpacking inspection 6 4 2 Installation requirements 5 4 3 Cable preparation 5 5 Installation 5 5 1 Installation recommendations and operations 6 5 1 1 Installation dra...

Page 5: ...therwise Bi1248 1200 would be overheating To avoid fire and electric shock make sure all cables selected with right gauge and being connected well Smaller diameter and broken cable are not allowed to...

Page 6: ...voltage is lower than 12 8V this device will stop working Smart alternator Euro 6 Through dip switch this device can be set to smart alternator mode After choosing this mode IGN signal or similar sig...

Page 7: ...tor Multiple battery chemical can be chose including lithium battery TBB premium II multiple stages charging algorithm Built in automatic temperature and voltage compensated charging Thermal controlle...

Page 8: ...Bi1248 1200 User Manual 4 3 Structure 3 1 Dimension 306 3282 8 170 291 6 85 200 4 5 301 6 Dimension 306 3 200 85mm Weight 3kgs...

Page 9: ...ethod air cooling Altitude 2000m or less meeting the derating requirements of GB3859 2 93 4 3 Cable and Fuse preparation Please refer to the table below for cable and fuse specifications Model Connect...

Page 10: ...off the power switch or external control signal to prevent Bi1248 1200 from working due to which may cause sparkling during the wiring process Please select the appropriate location with adequate vent...

Page 11: ...is 100A 3 12V terminal Positive terminal of starter battery the maximum current is 200A 4 BAT terminal Negative terminal of starter battery the maximum current is 100A 5 BAT terminal Negative termina...

Page 12: ...1 2 Battery Type setting OFF OFF AGM default OFF ON GEL ON OFF LFP ON ON OTHER 3 Alternator setting OFF Normal alternator ON Smart generator Euro 6 4 5 System working mode OFF OFF Stand alone mode ON...

Page 13: ...rminal BAT first and then connect the positive terminal 48V of the auxiliary battery and the positive terminal 12V of the starter battery respectively Connect one end of the negative cable to the term...

Page 14: ...RY_DO_NO1 Dry contact output normally open contact 10 DRY_DO_NO2 11 DRY_DI_NO1 Dry contact input normally open contact 12 DRY_DI_NO2 13 TEMP_BAT1 Service battery temperature sampling line 14 TEMP_BAT1...

Page 15: ...is strictly prohibited Check if the voltage and temperature compensation lines have been connected to the positive terminal of service battery If the generator is a smart generator confirm that the D...

Page 16: ...ndby Off others Boost mode Green On 12V battery is normal 12V battery charges 48V battery Flash standby Off others Alarm Orange Flash overheating of the radiator over temperature of the battery overvo...

Page 17: ...ard battery charging curve Battery types and bulk charging absorption charging voltage Table 8 Service battery types and bulk charging absorption charging voltage No Battery types Bulk charging voltag...

Page 18: ...e rating curve This device has built in intelligent temperature control and will reduce its output power in case of high working temperature reached Figure 8 Bi1248 1200 internal temperature and outpu...

Page 19: ...25A 100A Efficiency Max 94 Full load 91 Standby consumption 2mA Protection Input overvoltage alarm 14 9Vdc protection 16Vdc alarm 59 6V protection 60Vdc Output overvoltage alarm 59 6V protection 60Vd...

Page 20: ...Bi1248 1200 User Manual 16 TBB Power Co Ltd Web www tbbpower com Tel 86 592 5212299 Fax 86 592 5796070 Email service tbbpower com...

Reviews: