Standby temperatures must be set to maintain
hopper and freezing cylinder temperatures below
40°F (4.4°C).
Pressing the UP or DOWN arrow keys increases or
decreases the temperature by 1/2°, respectively.
Pressing the SEL key accepts the setting and
returns to the Service Menu screen.
Note:
Pressing the MENU key while in either
screen ignores any changes and returns to the
Service Menu.
Hopper Temp
This option allows the service technician to adjust
the hopper temperature in AUTO and STANDBY.
The Left/Right choice screen is displayed upon
selecting this option. (See Figure 40.)
HOPPER TEMP
LEFT
RIGHT
>
Exit
Figure 40
Pressing the UP or DOWN arrow keys moves the
arrow to “Left”, “Right”, or “Exit”. Press the SEL key
to choose the appropriate option. Selecting “Left” or
“Right” displays a second screen which allows the
technician to set the hopper temperature for that
side. (See Figure 41.)
<
COOLER
WARMER >
V
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
>
Exit
Figure 41
The “V” indicates the current setting. Pressing the
UP arrow key moves the “V” one position to the right
(warmer). Pressing the DOWN arrow key moves the
“V” one position to the left (cooler). Pressing the
SEL key accepts the setting and returns to the
Service Menu screen.
Viscosity Setting
This option allows the service technician to adjust
the viscosity at which the compressor turns off in
AUTO. The Left/Right choice screen is displayed
upon selecting this option. (See Figures 42 and 43.)
VISCOSITY SETTING
LEFT
RIGHT
>
Exit
Figure 42
VISCOSITY SETTING
VISC
=
2.8 AMPS
Change
>
Exit
Figure 43
Pressing the UP arrow key moves the arrow up and
pressing the DOWN arrow key moves the arrow
down. Pressing the SEL key with the arrow next to
“Exit” has no effect and returns to the Service Menu
screen. Pressing the SEL key with the arrow next to
“Left” or “Right” will display the respective viscosity
screen. (See Figure 44.)
VISCOSITY SETTING
VISC
=
2.8 AMPS
Current
=
0.0
Figure 44
Pressing the UP arrow key increases the viscosity
setting by 0.1 amp. Pressing the DOWN arrow key
decreases the viscosity setting by 0.1 amp. Pressing
the SEL key accepts the viscosity setting and
returns to the Service Menu screen.
Summary of Contents for C723
Page 2: ......
Page 39: ...35 Model C723 Controls Systems and Operations 140519 C723 Control Overview Figure 72 ...
Page 41: ...37 Model C723 Controls Systems and Operations 130409 Refrigeration Schematic Figure 73 ...
Page 52: ...48 Troubleshooting Model C723 Notes ...
Page 55: ...51 Model C723 Parts Notes ...
Page 56: ...52 Parts Model C723 150603 Model C723 Exploded View Figure 74 ...
Page 59: ...55 Model C723 Parts 140519 Model C723 Operator Parts Figure 75 ...