OPERATING PROCEDURES
6-5
Model 432
Operating Procedures
6
17. Install the front drip tray and splash shield beneath
the door spouts.
Figure
6-17
18. Lay the air/mix feed tube (optional) in the bottom of
the mix hopper.
Figure
6-18
19. Repeat steps 1 through 18 for the other side of the
machine.
Sanitizing
1. Prepare an approved 100 PPM (parts per million)
sanitizing solution (examples: 2-1/2 gal. (9.5 L) of
Kay-5
®
or 2 gal. (7.6 L) of Stera-Sheen
®
). Use warm
water and follow the manufacturer’s specifications.
2. Pour the sanitizing solution into the hopper and allow
it to flow into the freezing cylinder.
Figure
6-19
3. While the solution is flowing into the freezing cylinder,
brush clean the mix hopper, air/mix feed tube
(optional), and mix inlet hole.
4. Place the control switch in the WASH position. This
will agitate the sanitizing solution in the freezing
cylinder. Allow the solution to agitate for five minutes.
Figure
6-20
5. Place an empty pail beneath the door spout and
move the draw handle to the right. Draw off all the
sanitizing solution. When the sanitizer stops flowing
from the door spout, move the draw handle to the left
and place the control switch in the OFF position.
Summary of Contents for 432
Page 8: ...1 4 TO THE INSTALLER Model 432 To the Installer 1 Notes ...
Page 18: ...4 6 OPERATOR PARTS IDENTIFICATION Model 432 Operator Parts Identification 4 Notes ...
Page 34: ...9 2 PARTS REPLACEMENT SCHEDULE Model 432 Parts Replacement Schedule 9 Notes ...
Page 38: ...10 4 LIMITED WARRANTY ON EQUIPMENT Model 432 Limited Warranty on 10 Notes ...
Page 42: ...11 4 LIMITED WARRANTY ON PARTS Model 432 Limited Warranty on Parts 11 Notes ...