5-2
USER INTERFACE
Model 432
User Interface
5
Indicator Light–MIX OUT
The MIX OUT indicating light is located on the front of the
machine. When the light is flashing, the hopper is empty
and the mix supply needs replenishing. To prevent
damage to the machine, refrigeration discontinues
automatically when the MIX OUT indicator light
illuminates. Refrigeration will restart 30 seconds after the
mix supply is replenished.
Indicator Light–ADD MIX
The ADD MIX indicating light is located on the front of the
machine. When the ADD MIX indicating light is flashing,
the mix hopper has a low supply of product and should
be refilled as soon as possible.
Viscosity Adjustment
The viscosity (thickness) of the slush can be adjusted by
turning the viscosity adjustment screw located under the
control channel. Turn the viscosity adjustment screw
clockwise for a thicker product, or counterclockwise for a
thinner product. After making an adjustment, allow the
refrigeration system to cycle two or three times to
accurately evaluate the viscosity.
.