![tau DC20 Installation Manual Download Page 26](http://html.mh-extra.com/html/tau/dc20/dc20_installation-manual_821506026.webp)
26
3
ON
OFF
Keep the Dip switch in OFF
4
DOORS
DIRECTION
ON
Opening
towards the right
OFF
Opening
towards the
left
If the automatic door has a single leaf opening to the right, it is necessary to reverse
the controls of the dip switch 4 as follows: ON: opening towards the left - OFF: opening
towards the right (standard)
5
ON
OFF
Keep the Dip switch in OFF
6
ON
OFF
Keep the Dip switch in OFF
BATTERY CHARGER KEY
Key:
LED steady on;
LED flashing;
GREEN LED – battery charger
status
off
battery charger off;
flashing every 2 seconds
initial slow charge;
continuous flashing
under fast charge;
flashing every 4 seconds
in backup;
steadily lit
battery charged;
RED LED – fault diagnostics
off
everything OK;
steadily lit
FAULTY battery (cell voltage < than the minimum or …..)
continuous flashing
short circuit
flashing every 2 seconds
battery not connected
AUTOMATIC OPERATION RESETTING - REALIGNMENT
When the board is powered or if the status of the inputs is unknown, the software must realign the
automation to determine the initial position.
The direction of the realignment depends on the program selected and the command given.
ATTENTION: if there are any “motor” alarms, the automatic reset timer is inhibited.
DIAGNOSTICS LEDs AND BUZZER
DL1
DIAGNOSTIC
DL2 - Red
POWER SUPPLY 12 V
DL3 - Red
POWER SUPPLY 5 V
DL4 - Red
AUX POWER SUPPLY 24 V DC
DL5 - Red
INSIDE SENSOR
DL6 - Red
OUTSIDE RADAR
DL7 - Green
PHOTOCELL 1
DL8 - Green
PHOTOCELL 2
DC20 -
ENGLISH