![tau DC20 Installation Manual Download Page 21](http://html.mh-extra.com/html/tau/dc20/dc20_installation-manual_821506021.webp)
21
15 - 16
PHOTOCELLS
(N.C. contact)
Closed
None.
Opening
None.
Closing
Reverts motion and opens.
Open
Door won’t close until photocells are released.
In pause
None.
17 - 18
PRESENCE DETECTORS
TEST
17= + TEST
18= - TEST
CONNECTOR J16:
Terminals
Input/Output Door Status Function
19 - 21
EMERGENCY
(N.C.)
(21= Common
)
Closed
Opens in any program, except in “LOCKED”. When
dip # 1 on SW1 is set on ON opens also in “LOCKED”.
Opening
None.
Closing
Reverts motion and opens.
Open
Door won’t close until input is released.
In pause
None.
20 - 21
CLOSE
/LATCHING
RELAY
(N.O.)
DIP # 7 on SW1 on OFF
(21= Common
)
Closed
None.
Opening
Reverts motion and opens.
Closing
None.
Open
Closes in any program, except in “HOLD OPEN”.
In pause
None.
20 - 21
CLOSE/
LATCHING
RELAY
(N.O.)
DIP # 7 on SW1 on
ON
(21= Common
)
Closed
Opens in any program, except in “LOCK”.
Opening
Reverts motion and closes, except in “HOLD OPEN”.
Closing
Reverts motion and opens, except in “LOCK”.
Open
Closes in any program, except in “HOLD OPEN”.
IMPORTANT: Auto Close function is disabled.
In pause
Closes.
21 - 22
INTERLOCK
(N.C.)
(21= Common
)
Closed
Prevents the opening of the other door when the
Interlock is operating
Opening
None.
Closing
None.
Open
None.
In pause
None.
23 - 21
SIDE SENSOR
(N.C.)
(21= Common
)
Closed
None.
Opening
Opening continues at reduced speed.
Closing
None.
Open
None.
In pause
None.
24 - 21
STOP/
ANTI-PANIC
(N.C.)
(21= Common
)
Closed
The door does not open so long as the input is busy.
Opening
It stops the automation.
Closing
It stops the automation.
Open
The door does not close so long as the input is busy.
In pause
The door does not open so long as the input is
busy. Once free, the door closes at reduced speed
after 5 seconds.
NOTE: The STOP lock/function blocks any movement in progress of the automation, while
the ANTI-PANIC lock/function stops the movement in progress of the automation and
then resumes with a slow closing once the function is restored.
DC20 -