CONNETTORE J13
- sensor connection:
Terminals Function
Description
11 - 12
INTERNAL SENSOR
(N.O. contact)
Opens in “EXIT ONLY” and “AUTO”.
Door won’t close until sensor is released.
11 - 13
EXTERNAL SENSOR
(N.O. contact)
Opens in “ENTANCE ONLY” and “AUTO”.
Door won’t close until sensor is released.
11 - 14
OPENING SAFETY SENSOR
(N.C. contact)
Stops the door if it detects an obstacle/person
during the opening phase, and it resumes opening
when the obstacle/person is removed.
11 - 15
CLOSING SAFETY SENSOR
(N.C. contact)
Stops the door if it detects an obstacle/person during
the closing phase and it reopens.
16 - 17
SENSORS POWER SUPPLY
16= + 24V DC
17 = - GND
CONNETTORE J7
- battery connector
.
CONNETTORE J8
-
battery charger board connector.
CONNETTORE J9 -
connector for T-WIFI.
CONNETTORE J11
- connector for lid button.
CONNETTORE J12
- connection for T-LINESELF and EMERGENCY button:
18 - 20
EMERGENCY
(N.C.)
(20= commun)
Closed
Opens in any program, except in “LOCKED”.
When dip # 1 on SW1 is set on ON opens also in
“LOCKED”.
Opening
None.
Closing
Reverts motion and opens.
Open
Door won’t close until input is released.
In pause
None.
19 - 20
OPEN
/START
(N.O.)
(20= commun)
Closed
Open.
Opening
None.
Closing
Reverts motion and opens.
Open
None.
In pause
None.
20 - 21
22 - 23
MECHANICAL
SWITCH
20=
Commun
21= Switch B0
22= Switch B1
23= Switch B2
Connections:
Selector
Control Panel
1
20
2
21
3
22
4
23
WARNING: In case neither the mechanical selector it is necessary to jumper
wire terminals 20 - 22.
ENGLISH