12
it will propose the SETUP procedure automatically. To start the procedure, press the P1 key.
To start the SETUP of the stroke, press the P1 key, the DL1 LED will start to flash yellow and,
subsequently, the door will start a slow opening and closing maneuver to find the opening
and closing limit switches. At the end, the door will perform a complete opening and closing
maneuver at standard speed. Once the setup is done, the door must be closed and the DL1
LED must flash green.
The automation will therefore work with the standard factory settings. In case an interven
-
tion is required to change the operating parameters, the digital keyboard must be used by
accessing the various menus
SENSOR TEST SETTING
• Use only sensors which feature testing wires, connecting these to the wire terminals 8
and 10 of the controller DC18;
• Set DIP #15 and #16 on to ON in order to enable the test;
• Test will be performed at the beginning of each cycle (except when reversing motion)
.
BATTERY CHARGER KEY
Key:
LED steady on;
LED flashing;
GREEN LED – battery charger
status
off
battery charger off;
flashing every 2 seconds
initial slow charge;
continuous flashing
under fast charge;
flashing every 4 seconds
in backup;
steadily lit
battery charged;
RED LED – fault diagnostics
off
everything OK;
steadily lit
FAULTY battery (cell voltage < than the minimum
or …..)
continuous flashing
short circuit
flashing every 2 seconds
battery not connected
AUTOMATIC OPERATION RESETTING - REALIGNMENT
When the board is powered or if the status of the inputs is unknown, the software must
realign the automation to determine the initial position.
The direction of the realignment depends on the program selected and the command given.
ATTENTION: if there are any “motor” alarms, the automatic reset timer is inhibited.
ENGLISH