13
DIAGNOSTICS LEDs AND BUZZER
DL1
DIAGNOSTIC
DL2
POWER SUPPLY 12 V
DL3
POWER SUPPLY 5 V
DL4
AUX POWER SUPPLY 24 V DC
DL5
Red LED for signaling MOTOR POWER SUPPLY 40V DC
DL1 LED ERRORS
Key:
LED steady on;
LED flashing;
Automation warnings:
green - flashing every 4 seconds
automation closed – everything OK;
green - continuous flashing
automation moving (opening/closing);
green – quick flashing
automation pausing;
green – steadily lit
automation open;
/ alternating green/red - warning
setup to be performed
yellow – QUICK flashing
setup in progress
/ green/yellow – QUICK flashing
Parameter recalculation in progress / program
change
Allarmi automazione:
red - 1 error
photocell test failed
red - 2 error
obstacle present
red - 3 error
no voltage
red - 4 error
automation in unknown status
red - 5 error
automation timeout
red - 6 error
incorrect communication MASTER/SLAVE
red - 7 error
wrong parameters (generic error)
red - 8 error
incorrect winter stroke parameters
Motor alarms:
yellow - 1 error
encoder faulty or disconnected motor 1
yellow - 2 error
motor 1 faulty or disconnected
yellow - 3 error
motor 1 absorption exceeding the limits
yellow - 4 error
obstacle detected by encoder 1
yellow - 5 error
encoder faulty or disconnected motor 2
yellow - 6 error
motor 2 faulty or disconnected
yellow - 7 error
motor 2 absorption exceeding the limits
yellow - 8 error
obstacle detected by encoder 2
ENGLISH