31
16
Operation counter
It indicates the total number of au-
tomation maneuvers. By entering
function 16, the figures correspon
-
ding to the hundred-thousand and
ten-thousand will be presented;
by pressing the P2 key, it will go to
the thousands and hundreds; by
pressing P2 again, it will display
the digits corresponding to the
tens and units.
n. ma-
neu-
vers
17
NOT USED
18
OPEN/CLOSE fun-
ction selection
By enabling the function, the START
input becomes OPEN and the PE-
DESTRIAN START becomes CLOSE.
(yes = enable/no = disable)
YES
and
NO
NO
19
NOT USED
20
Steady flashing fun
-
ction selection
By enabling the function, the
flashing light will output a steady
light, without flashing. (yes = ena
-
ble/no = disable)
YES
and
NO
NO
21
Re-closing after pho-
tocell intervention
With the gate open with the au-
tomatic reclosing function active,
after an intervention of the photo-
cells the gate closes after 3 s. (yes =
enable/no = disable)
YES
and
NO
NO
22
Dead man
The gate only works by keeping the
START key pressed to open and the
PEDESTRIAN key to close
(yes = enable/no = disable)
YES
and
NO
NO
23
Selection of the sen-
sitive edge on the
pedestrian input
YES = use in pedestrian input to
connect a sensitive edge
No = use of the pedestrian input to
control the pedestrian opening.
YES
and
NO
NO