![tau D820M Installation Manual Download Page 23](http://html.mh-extra.com/html/tau/d820m/d820m_installation-manual_821502023.webp)
23
7.5 External receiver connection
0 V
DC
+12 V
DC
ST
AR
T
PEDESTRIAN
COMMON
1 2 3 4 5 6 7 8 9 10 11 12
D
L2
D
L4
D
L3
DL
1
LC
T1
LF
AERIAL
The intervention of the START input determi-
nes the total opening and closing of the gate.
The intervention of the PEDESTRIAN input
determines the partial opening and closing of
the gate.
To view the status of the START and PEDE-
STRIAN inputs, check DL4 and DL5 LEDs; these
inputs remain OFF in standby.
7.6 Key selector connection
ST
AR
T
PEDESTRIAN
COMMON
1 2 3 4 5 6 7 8 9 10 11 12
The intervention of the START input determi-
nes the total opening and closing of the gate.
The intervention of the PEDESTRIAN input
determines the partial opening and closing of
the gate.
To view the status of the START and PEDE-
STRIAN input, check DL4 and DL5 LEDs, these
inputs remain OFF in standby.
7.7 Sensitive edge connection on pedestrian input
COMMON
PARAMETER
VALUE
1 2 3 4 5 6 7 8 9 10 11 12
SAFE
TY EDGE
23 CF
The intervention of the SENSITIVE EDGE input
reverses the movement of the gate during
opening for about 20 cm.
To view the status of the SENSITIVE EDGE
input, check DL5 LED: this input remains ON
when in standby.
NOTICE: to enable the sensitive edge on
input no.2, enter parameter 23 and select
the CF value