![tau D820M Installation Manual Download Page 22](http://html.mh-extra.com/html/tau/d820m/d820m_installation-manual_821502022.webp)
22
7.2 Electric motor and flashing light connection
13 14 15 16 17 18 19
Maximum power: 50W and 230V AC
13 14 15 16 17 18 19
MOTOR
Three-phase 230 V AC or single-phase 230 V
AC motor
(with single-phase observe the
common connection on terminal 14 and do
not connect the capacitor between 13-15).
Maximum power 1100 W.
7.3 Photocell connection
1 2 3 4 5 6 7 8 9 10 11 12
RX
1 2 3 4 5
TX
1 2
COMMON
PHO
TOCELL
PHOTOCELL
0 V
DC
+12 V
DC
12 V DC power supply output for a maximum
of 500 mA; if 500 mA is exceeded, an external
transformer must be connected.
To view the status of the photocell, check DL6
LED, which remains ON when the photocell is
not engaged.
If the photocell is not used, build a bridge
between terminals 3-4.
7.4 Connection of stop buttons (for emergency STOP) and connection of sen-
sitive edge
ST
OP
COMMON
1 2 3 4 5 6 7 8 9 10 11 12
TOP INPUT:
The intervention of this input stops the move-
ment of the gate both in opening and closing.
To view the status of the STOP input, check
DL7 LED, which remains ON with STOP not
engaged.
If the STOP input is not used, build a bridge
between terminals 3-5.