26
12. PROGRAMMING OF THE STROKE
During this phase the current absorption curve is detected for management of
obstacle control (ampere-stop). In this phase is determined the behaviour that we
want the automation has when it will be in the standard operation.
P1
CLOSE
1.
Check that, by pressing the P1
key, the motor closes and brings
the automation to the closed posi-
tion, making sure that the DL9 LED
turns off when closing is complete.
If the gate opens, invert the cable
from terminal 13 - 15. Remember
that in the case of a single-phase
motor, the common cable must al-
ways be positioned in terminal 14.
P1
CLOSE
CH
2.
Make sure that the message
CH
= Door closed is shown on the
display, and release the P1 key.
P3
CLOSE
CH tE
3.
To reach the memorization of
the stroke, press the P3 key until
the message
tE
appears on the
display. Release the P3 key.
START
tE
OPEN
4.
Press and release the START key.
The gate begins to open at cycle
speed.