14
D703M
24
ENCODER signal (WHITE), ENCODER operation is governed by dip switch 5 (only for
motors with ENCODER);
25 - 26
GATE OPEN LED output; 24Vac, max. 3W; the LED lights up at the same frequency as
the fl ashing light throughout the opening and closing manoeuvres; it then stays on when
the OPEN LIMIT SWITCH (FCA) is reached and switches off when the CLOSED LIMIT
SWITCH (FCC) is reached;
27 - 28
24Vac power output (only for the photocell transmitter) max. no. 1 photocell transmitter;
29 - 30
24Vac auxiliary power output (power input to photocells or other devices);
31 - 32
AERIAL input (earth=31, signal=32) (only for RX 40.665MHz);
33 - 34
2nd RADIO CHANNEL output;
C
radio board connector.
LOGIC ADJUSTMENTS
TRIMMER
T.L.
Work Time adjustment: from approx. 5 to 240 seconds;
T.C.A.
Automatic Closing Time adjustment: from approx. 5 to 120 seconds (see dip switch 1);
FR.
obstacle detection sensitivity adjustment (only for motors with encoder).
N.B.:
turn the TRIMMER clockwise to increase adjustments; turn it anticlockwise to de-
crease.
Dip switches
1 on:
after opening, the gate automatically closes when the delay set on the T.C.A. trimmer ex-
pires;
off:
a command is required to close the gate;
2 on:
with automatic closing enabled, a sequence of open/close commands causes the gate to
OPEN-CLOSE-OPEN-CLOSE etc.;
off:
in the same conditions, the same command sequence causes the gate to OPEN-STOP-
CLOSE-STOP-OPEN-STOP (step-by-step) (see also dip switch 9);
3 on:
Man Present; the automation system will continue to open or close as long as the OPEN or
CLOSE buttons are held down. The gear motor will stop when the button is released;
off:
normal (or pulse); when the OPEN, CLOSE or the PP button is pushed, the automatic sys-
tem performs a complete opening or closing manoeuvre;
N.B. In the Man Present mode, the PP input (n° 13) is disabled, as is the radio receiver.
4
not used;
5 on:
encoder disabled (obligatory if the motor is not fi tted with an encoder);
off:
encoder enabled (only for motors with encoder);
6 on:
pre-fl ashing and “photocell test” function enabled;
off:
pre-fl ashing and “photocell test” function disabled;
7 on:
after the photocell contact triggers (input 16 - 18), the automation system closes after 5
seconds;
off:
function disabled;
8 on:
the gate works as set by dip switch 2
off:
the gate ignores the close command during the opening cycle;
9 on:
during opening, the photocell cuts in to stop the gate until the obstacle is removed. During
closing, it stops the gate and then totally reopens it.
off:
during opening, the photocell does not trigger while during closing, it behaves as if the dip
switch were on;
10 on:
braking enabled;
off:
braking disabled;
N.B. The braking system activates whenever the motor must stop (FCC - FCA - STOP –
change of direction) and reduces the inertia accumulated by the gear motor during
movement.