31
Marchesan Implementos e Máquinas Agrícolas “TATU” S.A.
TCA 13500
Adjustments and operations
NOTE
When working with grains, it is necessary to remove the telescopic tube
with hose and the fertilizer nozzle. Disconnect the wires of the telescopic
switch and place the nozzle for grains. Then, connect the 'female' plug that
comes along with the 'male' plug, so the switch that is located behind the
oil reservoir can work.
The cable (A) must be connected as follows:
Connect the blue wire on the positive pole and the black wire on the negative
pole of the tractor battery. A wrong connection may blown the fuse.
A
Control valve
Light
Hydraulic
control valve
Telescopic tube
Activation button
Fuse 10A
Electromagnetic hydraulic control valve system
There are two activation buttons, being one on the telescopic nozzle and one behind
the oil reservoir. They both have the same function: turn the hydraulic activation to on or off.