9.4 Operation screen in safety system of boiler return temperature

Fig.84. Screen of mixer operation (protection of the return temperature)

Boiler
temperature

Direction
of valve
move

Icons of
additional
data

Icon of
MIXER screen

Return
temperature

Mixer
pump

Preset
temperature
of the protection
of the return

F1=setting
the basic
parameters

F2=manual
operation

!

Direction of valve movement"

means opening the valve for the return water from the

CH system (respectively

- closing the return water and mixing it with the water from the boiler to

increase the return temperature).
If the valve drive runs, the arrow blinks. Lack of the arrow means in the next cycle the valve remains
motionless. Pressing the F1 button enables the change of the basic parameters of the mixer
:
# <62>"TempMIXER" - preset minimum temperature of the boiler return

By pressing the F2 button you can transition to the manual operation in order to test the correctness of
mounting and operation of the valve.

Icon of
MIXER and
MANUAL screen

Time to end of
manual
operation

Direction
of valve
move

F2=end of
manual
operation

F1=change of
direction of valve
move

Icon of
additional
data

!

The screen appears at the setting <60>(

ModeMIXER

)=RETURN

Fig.84A Screen of mixer operation (protection of the return temperature)- Manual mode

Manual operation is restricted in time. It ends automatically after 2 mins since last pressing

the F1 button

!

LEVEL OF PARAMETERS 2

PARAMETERS CAN BE CHANGED AT UNLOCKED PASSWORD

No

NAME

RANGE

SETTING

FUNCTION

2X

21

Temp-

ALARM-

BOILER

75...95

o

C

90

o

C

Boiler temperature at exceeding of which
the alarm activates

22

Temp-

STOP-

BOILER
(water)

20...45

o

C

35

o

C

Boiler temperature below which the automatic operation
is switched off, that is, the transition to the stop state
occurs. The switch-off happens if for 45min (parameter
<23> that state is active. Function is off with the flue gas

sensor

23

Time-

STOP-

BOILER
(water)

5...60min

45min

The time of keeping up the low boiler temperature after

which 'the transition to the stop state follows.

3X

blower

DEFAULT

boiler

30

-

ADJUSTABLE

-

31

10..100%

100%

32

1

10

o

C

2

o

C

38

2..10

o

C

5

o

C

39

0

100%

100%

ON/OFF

ADJUSTA-

BLE

REG1
REG2

Adjusting the blower control to the motor type:

ON/OFF-operation without adjustable rotation
ADJUSTABLE- typical motors
REG1- motors type RV-14
REG2 - motors type WPA-07

C
BLOWER

ontrol-

Max
Motor
Speed

-

-

Hysteresis
BLOWER

-

ZoneOf
Control

-

RangePID

Motor rotation that defines maximum efficiency of
the blower.

(e.g. if <31>=85% and on the display the efficiency
is 100% it means the motor reached the level <31>=85%
of its maximum power.

All the other settings regarding

the blower are in relation to this value

Hysteresis of turning on the blower operating
without adjustable rotation, that is, at <30>=ON/OFF

Ranges of boiler temperature that correspond to
adjustable rotation.
Impact of the PID algorithm on the control of
the blower. 0% means switching off the PID

24

Temp-

-

STOP-

BOILER
(flue gas)

Flue gas temperature of the damping threshold.
The controller detects the damping state if the flue gas temperature is
below <24> and active for the time <25>
Setting <24>=500 C turns off this function-
Transition between the phases is controlled by the water temperature

o

24d

Temp-
HYSTERESIS
(24)

The controller detects the fired-up state if the flue gas
temperature is above <24>+<24d>

25

Time-

STOP-

BOILER
(flue gas)

1. .90min

10min

36

o

C

250

o

C

MAXtemp.

of

FlueGas

If the flue gas temperature exceeds <36> then
the blower efficiency is reduced to <37>
Setting <36>=500 C turns off this function-
there

s no performance reduction of the blower

o

36d

10..90

o

C

20

o

C

Temp-

(36)

Hysteresis

Temperature drop of the flue gas below <36>-<36d>
causes the return to the normal operation.

37

Blower-
Rotations-
Reduction

If the flue gas temperature exceeds <36> the efficiency
of the blower is reduced to <37> (if it

s higher)

30... 500

o

C

50

o

C

10... 90

o

C

30

o

C

The controller detects the damped state if the flue gas
temperature is below <24> and that state is active
for the time <25>

100..500

10..90%

40%

Summary of Contents for RT-14

Page 1: ...thermostat 94 C 230V 50Hz Power consumption without load 4W Max connection power 750W Operation conditions 0 50 C humidity10 90 no condensation Housing protection class IP41 Fuse 6 3A 250V P of blower...

Page 2: ...ILER 45min the temperature doesn t increase then the blower turns off an The given temperatures relate to the situation when the sensor of the flue gas is inactive After connecting the flue gas sensor...

Page 3: ...r our sole responsibility that the product Controller of the Heating System model RT 14 PN EN 55022 2011 EMC IT devices Characteristics of radioelectric noises Acceptable levels and measurement method...

Page 4: ...TimeStopPumpCH o o The controller protects the system from freezing automatically switches on the circulating pump if themeasuredtemperatureisbelow The controller realizes an after season rundown of t...

Page 5: ...the WAW pump afterloadingthecontainercausesthenormaloperationoftheCH pumptocomeback the pumps run as in PRIO mode Additionally during loading the container the presettemperatureoftheboileris raisedto6...

Page 6: ...ents onthecontrolpanel fig 8 The operation state is presented on the graphic display 2 The screens inform about the operation of devices temperature of sensors they make it possible to change the para...

Page 7: ...21 TempALARM_BOILER 61 TempALARM FLOOR o 9 2 Screen of boiler operation Thescreenfeaturescurrenttemperatureof theboilerandrotationof theblower Fig 82 Screen of boiler operation 18 WARNING WE INFORM T...

Page 8: ...ler in case of the room thermostat operation TempBOILER TempTHERMOSTAT 17 PASSWORD 9999 HAS CONSIDERABLE MEANING IT CAUSES THE REACTIVATION OF THE PREVIOUS PASSWORD IF PRESENT WITHOUT IT BEING DISCLOS...

Page 9: ...he cyclical run After that time the CH pump runs for 45secs Temperature hysteresis of turning on off the pumps The temperature difference between turning on and turning off the pumps It prevents often...

Page 10: ...60min 45min The time of keeping up the low boiler temperature after which the transition to the stop state follows 3X blower DEFAULT boiler 30 ADJUSTABLE 31 10 100 100 32 1 10 o C 2 o C 38 2 10 o C 5...

Page 11: ...ways when the controller is on Switching off the backlighting means it gets the value defined by the next parameter 15 Minimum LCD backlighting it s valid at the negative LCD The value 0 means a full...

Page 12: ...t Parameter value change Upper and lower change limit THE PARAMETERS ADJUST THE CONTROLLER TO THE FEATURES OF THE BOILER AND THE CH SYSTEM THEIR CHANGE SHOULD BE CONSULTED WITH THE PRODUCER OF THE BOI...