19. System Preferences
Perform the following to set the WiFi, beeper, language,
measurement system, and water flow rate system
preferences.
Turn on the system by pressing the standby
button.
Wait approximately 2 minutes until the LOG
IN screen is displayed.
••••••
1 2 3
4 5 6
7 8
0
9
x
Press the LOG IN key and enter your
administrative password.
The prep guide will appear. Touch the OK
button to move to the home screen.
Figure: 40
From the home screen, press the right
arrow button to access the system settings
menu.
Press the Prefs button to access system
preferences.
Press the WiFi button to configure the
system WiFi. WiFi must be turned on when
the Intelli-Track reporting system is in use.
Press the beeper button to set the safety
beeper on or off. When set to ‘ON’ the
beeper will sound while the machine is
running.
Press the language button to select
English, Spanish, or German for the system
interface.
Press the measurement button to configure
the measurement system to metric or
imperial.
Press the water flow button to configure the
system flow rate from 1.1 to 2.6 liters per
minute.
Press the OK button to exit the system
preference menu.
20. Commissioning After Storage
If the machine has been in storage, the following items must
be reviewed:
The robotic floor scrubber system must be
acclimated to the operating environment.
Failure to do so can result in condensation
inside the machine, shortening the life of
critical components. Allow the machine to
acclimate one hour for every 9° F (5° C).
Gel cell batteries will lose charge if not
maintained while in storage. Ensure the
batteries go through a full charge cycle
before turning on the system.
21. Weekly Safety Device Check
To ensure the safe operation of this machine, the operator
must periodically verify the operation of the system safety
devices. The following operational safety device check
should be performed on a weekly basis.
If any safety device fails the operational
safety device check, the machine must be
serviced by a trained service technician. Do
not use the system if any safety device is
not operating properly.
21.1. Emergency Stop Button Check
Perform the following steps to verify operation of the
Emergency Stop button:
Turn on the system by pressing the standby
button.
Wait approximately 2 minutes until the LOG IN screen is
displayed.
Figure: 41
Press the Emergency Stop button.
Verify that the system alerts the user with
three audible beeps and the user interface
displays the attention symbol and the
words.
Emergency Stop pressed
Twist and release to resume
If the system fails the Emergency
Stop button operational check, turn off
immediately by pressing and holding the
standby button. Do not use the system,
it must be repaired by a trained service
technician.