34
Fig 6.4.1D Effects of Elevation of Trajectory
Fig 6.4.1E Effects of wind on reach
This graph is approximate only.
Critical applications should be tested in actual conditions to verify adequate reach.
This graph shows approximately how a moderate wind can affect stream reach.
0
10
40
20
80
0
40
80
120
160
200
240
280
320
360
HORIZONTAL DISTANCE (FEET)
2.50 INCH TIP, 100 PSI, 1860 GPM
VERTICAL
DIST
ANCE
(FEET)
NO WIND
20 MPH TAILWIND
20 MPH HEADWIND
0
25
50
75
100
VERTICAL
DIST
ANCE
(M)
HORIZONTAL DISTANCE (M)
0
20
40
60
80
100
120
140
160
180
200
0
40
80
120
160
200
240
280
HORIZONTAL DISTANCE (FEET)
2 .50 INCH TIP, 100 PSI, 1860 GPM
VERTICAL
DIST
ANCE
(FEET)
75 DEGREES
60 DEGREES
45 DEGREES
30 DEGREES
0
20
40
60
0
20
40
80
60
HORIZONTAL DISTANCE (M)
VERTICAL
DIST
ANCE
(M)
1 ft = 0.3048 m
CURVE
A
B
C
D
E
CURVE
A
B
C
D
E
GPM
FLOW
300
600
1000
1500
2000
LPM
FLOW
1100
2300
3800
5700
7500
LBS
REACTION
160
300
510
760
1000
KGF
REACTION
70
140
230
340
450
0
10
20
30
40
50
60
70
80
90
METERS
0
10
20
METERS
0
10
20
30
40
50
60
70
80
0
20
40
60
80
100
120
140
160
180
200
220
240
260
280
300
HORIZONTAL DISTANCE (FEET)
A
B
C
D
E
MASTERSTREAM 2000, 100 PSI (7 BAR, 700 KPA)
VERTICAL
DIST
ANCE
(FEET)
EXCEL\MISC\RAN_MON
6.4.2 MASTERSTREAM 2000 NOZZLES
Automatic nozzles maintain a constant pressure by adjusting their orifice to match the available flow. Consult the nozzle manufacturer
for maximum flow and pressure range. In all cases do not exceed 2000 gpm (7,600 LPM). TFT's Masterstream 2000 nozzle has a 300-
2000 gpm flow range. Masterstream 2000 Nozzle operating instructions (Item Number LIM-030) is available on TFT's website:
www.tft.com