DRAFT
- 20 -
17.0
Service automatic feeding system
The Electrical Hydrostatic Feeding System is a complete unit based on 3 basic components as
electric motor (7), hydrostatic variator (8) and gear (9).
When delivered the speed control is set to a correct limit.
Do not change this!
Service
When delivered the hydrostatic unit (8) is filled with oil,
tested and prepared to be used directly.
Basically this is a locked system prepared for up to 2000
hours usage before an oil change is required.
It is however recommended to control the oil level
through the inspection glass (10), and refill if necessary.
The oil input (11) is located outside frame (12).
Change of oil: Remove cap (11). Open drain plug (13) to
pour out
the old oil. Refill new oil as recommended below.
Recommended grade of oil: Esso INVAROL EP 46; 0,5 L
17.1
Trouble shooting
Forward feeding do not work?
1. Did you connect the gear connection? (Item 2 page 11)
2. Did you start the feeding motor? (Item 4, page 11)
3. Did you choose correct motor running direction? (Item
16, page 8)
4. Check that main fuse is turned on. (Page 9)
5.Check that the chain between gear and rear wheel is
undamaged.
If further problem, call for assistance and refer to the information on the technical plate for motor
as well as the variator shown at the illustration to the left.