![Target Auger Manager User Manual Download Page 25](http://html1.mh-extra.com/html/target/auger-manager/auger-manager_user-manual_3602949025.webp)
25
TA
RG
ET
G
ES
TIO
N D
E V
IS
TAR
GET
G
ESTIO
N D
E VI
S
rev.
04
6.2
.4
.1
Cou
rbe
d
u t
em
ps
d
'a
rrê
t m
ax
im
um
Une
c
ourbe
pe
ut ê
tre
dé
fini
e a
fin
de r
égl
er
aut
oma
tique
me
nt l
e
te
mps
d
'a
rrê
t m
ax
im
um d
es
v
is
au
fi
l d
es
jou
rs
.
Ch
aq
ue c
our
be c
omp
orte
hui
t p
oint
s e
t pos
sè
de 2
ty
pes
de
do
n-
né
es
: un
numé
ro
de j
our e
t l
e t
em
ps d'
arr
êt
ma
xim
um de
la
v
is
pour
ce
jour
. L
e c
ont
rôl
eu
r p
eut
ai
ns
i a
ju
ste
r l
a l
im
ite
d'
ala
rm
e du
te
mps
d
'a
rrê
t m
ax
im
um
d
e f
aç
on
lin
éa
ire
en
tre
le
s p
oint
s c
on
sé
cu
-
tif
s de
la
co
urbe
. L
ors
que
le
de
rn
ie
r po
int
d
e l
a c
ourbe
es
t a
tte
in
t,
le
te
mps
d'
arr
êt
ma
xim
um pour
c
e j
our e
st
ma
int
enu
jus
qu’à
c
e
qu
'u
n no
uv
el é
le
va
ge
d
éb
ute
.
NO
TE
S:
Le
s h
uit
poi
nts
de
la
cou
rb
e d
oiv
ent
ob
liga
toi
re
me
nt ê
tre
enr
egi
s-
tré
s.
Si
huit
point
s ne
s
ont pa
s r
equi
s,
ré
péte
z l
e de
rni
er
te
mps
d'a
rrê
t m
ax
im
um s
ur
le
s p
oin
ts
inu
tili
sé
s o
u d
im
in
ue
z le
nu
mé
ro
d
u
jo
ur.
C
ett
e d
im
in
uti
on
en
tra
în
e l'
arr
êt
de
la
pr
og
re
ss
io
n d
e la
co
urb
e.
GR
AP
HIQ
UE
:
Co
urb
e
du
t
em
ps
d
'a
rrê
t
ma
xim
um
TE
MP
S
D’A
RR
ÊT
M
AX
(h
:m
)
JO
UR
S
J1
J1
0
J1
5
10
:0
0
J2
0
J2
5
J3
0
J3
5
J4
0
4:0
0
5:0
0
6:0
0
7:0
0
8:0
0
9:0
0
J4
5
25
TARGET AUGER MANAGEMENT SYSTEM
TARGET AUGER MANAGEMENT SYSTEM rev.04
6.2.4.1 Maximum Off Time Curve
You can define a curve to get an automatic adjustment of the maxi-
mum off time over time.
A curve is defined using up to eight points. Each point specifies a
day number and an off time alarm limit for that day. The controller
will change the alarm limit every day in a linear fashion between
consecutive points of the curve. When the last point of the curve
is reached, the maximum off time for that day is maintained until a
new batch starts. The highest possible day number is 450.
NOTES:
All points of the curve must be specified. If eight points are not
needed, repeat the last max run time value for each unnecessary
point or decrease the day number: if the day number is decreased,
the curve remains at the previous point and ignores all following
points.
GRAPHIC:
Max Off Time Curve
MAX
OFF TIME
(h:m)
DAYS
D1
D10
D15
10:00
D20
D25
D30
D35
D40
4:00
5:00
6:00
7:00
8:00
9:00
D45
Summary of Contents for Auger Manager
Page 36: ...NOTES NOTES NOTES NOTES...