![Target Auger Manager User Manual Download Page 16](http://html1.mh-extra.com/html/target/auger-manager/auger-manager_user-manual_3602949016.webp)
16
TARGET AUGER MANAGEMENT SYSTEM
TARGET AUGER MANAGEMENT SYSTEM rev.04
Time of Reset:
This is the time at which the daily con-
sumption and the maximum motor tem-
perature values are logged in the histo-
ries. It should normally be set to
11h59PM.
No Alarm on Start New Batch:
The auger run time is likely to be higher
than usual at the beginning of a batch
since the feed lines are totally empty.
Enable this function to disable run time
and off time alarms on the first day of
each batch.
Use Alarm Shutdown Schedule?
Select "Yes" to define a period of time during which no alarm is set off.
If an alarm condition occurs during this period, the controller responds
as usual, but postpones the activation of the alarm relay until the end of
the schedule. This function is useful to avoid sounding alarms during
night for instance.
Alarm off – From:
Time at which the alarm shutdown schedule starts.
Alarm off – To:
Time at which the alarm shutdown schedule ends.
14.1 Inst. settings
Time Display: AM/PM
# of Augers 10
Temp. units: °F
Weight units: lbs
Time of reset:11:59P
No Alarm on start
new batch: No
Use Alarm Shutdown
Schedule: Yes
Alarm off from12:00A
To 12:00A
16
TA
RG
ET
G
ES
TIO
N D
E V
IS
TAR
GET
G
ESTIO
N D
E VI
S
rev.
04
He
ure
d
e s
au
ve
gard
e :
Ré
gle
r l
'h
eu
re
à
la
qu
elle
le
s d
on
né
es
s'a
jo
ute
nt
au
x h
ist
ori
qu
es.
L'
âg
e d
es
an
im
au
x a
ug
me
nte
d'
un
jo
ur
à c
ett
e
he
ure
. C
e p
ara
mè
tre
de
vra
it
norm
a-
le
me
nt ê
tre
ré
glé
à
11
h59
P.
Jo
ur 1
sa
ns a
la
rm
e :
Il
es
t po
ss
ib
le
q
ue l
e t
em
ps
de
ma
rc
he de
s v
is
soi
t pl
us é
le
vé
lor
s
du pr
em
ie
r j
our d'
un é
le
va
ge pui
s-
qu
e le
s li
gn
es
so
nt
co
mp
lè
te
me
nt
vi-
des
. L
ors
que
ce
tte
fon
cti
on
es
t ut
i-
lis
ée
, a
ucune
a
la
rm
e de
te
mps
de
ma
rc
he e
t de
te
mps
d'
arr
êt
n'e
st
déc
le
nché
e a
u pr
em
ie
r j
our de
ch
aq
ue
él
ev
ag
e.
Su
sp
en
sio
n d
es
al
arm
es
?
Ré
gle
r à
"O
ui"
po
ur
dé
fin
ir
un
e p
la
ge
de
su
sp
en
sio
n d
es
ala
rm
es
. S
i u
ne
si
tu
ati
on
d'
ala
rm
e s
urv
ie
nt
au
co
urs
de c
ett
e pé
riode
, l
e c
ontrôl
eur
ré
agi
t c
omm
e à
l'
habi
tude
m
ais
re
ta
rd
e l
e dé
cle
nc
hem
ent
de
l'
ala
rm
e j
usqu
'à
la
fi
n d
e l
a pl
age
de
sus
pens
io
n.
Ce
tte
fon
cti
on
es
t p
ra
tiq
ue p
our
em
pê
che
r l
e dé
cle
n-
che
me
nt d
'a
la
rm
es
pe
nda
nt
la
n
uit
p
ar
ex
em
ple
.
Su
sp
en
sio
n –
de
:
He
ure
à
la
que
lle
le
d
éc
le
nc
he
me
nt
d'a
la
rm
es
es
t s
uspe
ndu
:
Su
sp
en
sio
n –
à
:
He
ure
à
la
que
lle
pr
en
d f
in
la
p
éri
od
e de
su
sp
en
sio
n de
s a
la
rm
es
.
14
.1
Re
gl
ag
es
Af
f.
H
eu
re
:
A
M/
PM
#
de
v
is
:
10
Un
it
es
t
em
p.
°F
Un
it
es
p
oi
ds
l
bs
He
ur
e
sa
uv
:
1
1:
59
P
Jo
ur
1
s
an
s
al
ar
me
?
N
on
Su
sp
en
si
on
de
s
al
ar
me
s
?
O
ui
Su
sp
en
dr
e
de
12
:0
0A
a
1
2:
00
A
Summary of Contents for Auger Manager
Page 36: ...NOTES NOTES NOTES NOTES...