Taramps TW 30 G4 Manual Download Page 17

+

Configurar

1X = Desabilita
2X = Liga s/ Trava
3X = Liga e Trava
4X = Liga e trava
desliga e destrava

+ +

IGNIÇÃO

ON

START

OFF

MASTER

PORTA ABERTA

Selecionar a função Beep 16

+ +

IGNIÇÃO

ON

START

OFF

MASTER

PORTA ABERTA

Selecionar a função Beep 15

To change, press the Master key the number of times referring to the desired 
function. Each time you press the Master, the alarm confirms with 1 beep. 
After turning the ignition off , the alarm will confirm the new setting with 
beeps.

+

MASTER

4 Beeps

 = Turns  On and Lock s/ Turns Off and Unlocks

- With the door open, switch on the ignition.

Programming by Master

- The alarm responds with the current setting:

2 Beeps

 = Turns on the alarm without locking

- Hold the master pressed until beep 16.

3 Beeps 

= Turns on the alarm and locks

16) Turn Alarm  on by distancing:

This function is used to turn on the alarm only when pulling the TR2-P G4 remote control away 
from  the  vehicle.After  turning  off  the  ignition,  opening  and  closing  the  vehicle  door,  and 
moving the control beyond the transmission range, within 15 seconds the alarm will turn on.
According to the setting the alarm will:

1st Beep =

 Disabled, the alarm will only turn on/off when pressing the Control Buttons.

2nd Beep =

 Turns on the alarm by moving the control away without locking the doors, it will 

only turn off the alarm by pressing the control's Off button.

3rd Beep =

Turns the alarm on  by pulling the control away and locks the doors, it will only turn 

off the alarm and unlock the doors by pressing the Off button on the control.

4thBeep =

 Turns  the alarm on  by pulling the control away and locks the doors. Turns off the 

alarm and unlocks the doors by pressing the control's Off button or by bringing the TR2-P G4 
control closer to the vehicle and waiting for the automatic transmission.

ATTENTION: EXCLUSIVE function of the TW20 and TW30 G4 range with TR2-P G4 control. 

15) Open and Close Automated Gate - 

exclusive to TW30 G4 

Installation:

- Clone the original gate control in the TW30 G4 central.
Attention:  Function  compatible  only  with  operators  that  use  the  CODE  LEARNING  code 
system.

Operation:
With the ignition on, doors closed, press the high beams key (flasher) twice to open or close the 
gate.

- Connect the MR wire to the high beam flasher signal.

It is not necessary to do any type of programming in the gate operator central.

Programming:

- With the door open, turn the ignition on.
- Hold the master pressed until beep 15.
When releasing the master, the siren will sound a long 
beep.
- Hold pressed the button  that opens the gate until the 
alarm beeps 3, confirming the  recording.
- Turn off the ignition to exit programming.

+

Clone

17

Summary of Contents for TW 30 G4

Page 1: ...MANUAL AUTOMOTIVE ALARM Wireless communication with theAlarm Center TW30 ...

Page 2: ...ssional Thisproductisintendedtomakeitdifficultorinhibitthetheft robberyofthevehicle orobjectsin itsinterior During installation use only a multmeter to measure voltage 1 Before Starting ATTENTION We recommend reading this manual completely before proceeding with the installation of this product BASICALARM OPERATION Whenturning the alarm on byremotecontrol if the vehicle has audio equipment power win...

Page 3: ...basis that is it is not entitled to protectionagainstharmfulinterference evenfromstationsofthesametype andmaynotcauseinterferencetosystemsoperatingonaprimarybasis Replacing the Control Battery USE A HIGH QUALITY BATTERY Carefully open the plastic box from the sides Replace the battery observing the polarity and Use CR2032 batteries BUTTONS HOME Tr2 Control TR2 P PRESENCE CONTROL Controls Functions...

Page 4: ...eOpenDoor Item9 1 Note 4flashesontheturnsignals 4beeps indicate that there was a trigger when the alarmwasactivated Item12 1 2flashesonturnsignals 2sirenbeeps 2flashesonturnsignals Note 4 flashes on the turn signals indicate that there was a trigger when thealarmwasactivated Item12 1 Press for2seconds with alarmon 6 Panic 1 Long beep confirms ultrasound cancellation and window close Ultrasound operates...

Page 5: ...il you hear the desired ring 1 beep ENABLE 2 beeps DISABLE 1 beep ENABLE 2 beeps DISABLE 13 BROWN WIRE SETTING see Item 13 1 1 beep Reads Negative Switch 2 beeps Reads Positive Switch 3 beeps open close Gate 4 beeps Headlight Signal On Off 5 beeps Auxiliary 2 14 BLACK YELLOW WIRE SETTING see Item 14 5 1 beep Auxiliary Aux 3 Pulse 2 beeps Aux Output 3 Retention 3 beeps Headlights control 4 beeps Hor...

Page 6: ...onOFF ActivatePresenceFunctionintheAlarmCentral Afterturning theignitionofftthealarmwillconfirmthenewsettingwithbeeps Tochange pressoncetoEnableortwice 2x 1Beep PresenceFunctionON Thealarmwillrespondinforming Withthedooropen turntheignitionon Thealarmwillrespondinforming Withthedooropen switchontheignition 1Beep Blockingin1Minute Holdthemasterpresseduntilbeep9 Settimetolock 1 2or3minutes 2Beeps 2Min...

Page 7: ... every 2 seconds Operation Itisnotnecessarytomovethecontrolawayfromthevehicle totestthelock simplydisablethe automatictransmissionoftheTR2 Pcontrol turn theignitionon closethedoorsandwait It is used to test the range of automatic transmission in the Presence function With the automatic transmission of the presence function activated in the control and the function activatedin the alarm control pan...

Page 8: ...sterpressedfor3seconds TheultrasoundLED will valetfunctionandreturntonormaloperation flash3timesconfirmingactivation Tocancelthe IGNITION OFF O N START O F F MASTER DOOR CLOSED 3 Seconds With the door open switch on the ignition Set time to lock 1 2 or 3 minutes hold the master pressed until beep 9 The alarm will respond informing 1 Beep Lock in 1 Minute 2 Beeps Lock in 2 Minutes 3 Beeps Lock in 3 M...

Page 9: ...r turning on the ignition doors will be locked and unlocked by turning the ignition off It will not lock if a door is left open or turn on the ignition before closing the door It is possible to cancel the unlock when you turn off the ignition items 6 4 and 6 10 6 CANCELLING ULTRASOUND When turning the alarm on and canceling the ultrasound the power windows will not be closed To close the item 5 9 wi...

Page 10: ...gative switch 3 Open Close Gate 5 Auxiliary Output 2 Fix on the vehicle windshield 10cm below the roof Left Side Receiver Right Side Transmitter 13 Black 6 Yellow 7 Red 8 Green negative door switch Gray Gray ENGINE LOCK MAX 20A Illustrative images 16 Purple Audio Equipment ACC audio equipment Max 200mA 15 Black White 14 Black 12 Blue Ignition 11 Red Black UNLOCK Output to Power Window Closing Modu...

Page 11: ...nforming 1 Beep Universal 2 Beeps VW G5 Set Signal for Window Electric Lock activation 6 Beeps MOBI Hold the master pressed until beep 11 To change it press the Master key 4 times referring to theVW G6 G7 signal Each press on the Master the alarm confirms with 1 beep After turning the ignitionoff thealarmwillconfirmthenewsettingwith4beeps MASTER Attention The trunk opener function will only work in v...

Page 12: ... located above the acceleratorpedal DONOTconnectRed BlackandRed Yellow lockandunlock wires 11 3 FIAT Mode Palio Idea Punto and Linea with automated power windows closeand open ConnecttheGreen Blackalarmwiretopin8ontheoriginalcentral tothePalioandIdea linelocatedbehindtheglovecompartment OnLineaandPunto Red Blackwireinthecentral locatedbehindthefusebox 11 4 VW G6 and G7 mode Gol Saveiro Voyage gene...

Page 13: ...tion Click 1 Time 2 Times 3 Times 4 Times 5 Times Alarm Response Sensor Sensitivity 20 10 Factory Standard 10 20 1 Beep 2 Beeps 3 Beeps 4 Beeps 5 Beeps Decrease Increase Table Follows below Fix the sensors to the vehicle s windshield 10cm below the roof Ultrasound Sensors come with digital sensitivity adjustment Only change the default setting if necessary New Transmitter See page 10 12 G2 Ultraso...

Page 14: ... is compatible only with operators that use the CODE LEARNING code system Withtheignitionon 2toucheson thehighbeamskey flash toopenorclosethegate Itisnotnecessary toapplyanytypeofprogramminginthegateoperatorcentral Forinstalling inadoorswitch hoodortrunkwithaNegativesignal whenopen Forinstalling inadoorswitch hoodortrunkwithaNegativesignal whenopen Installation To change it press the Master key the...

Page 15: ...eeps MASTER 13 2 Auxiliary Output 2 Setup brown wire After 10 seconds with the ignition on the ultrasound LED will flash warning that the headlight isoff turningontheheadlighttheLEDgoesout Whenturning theignitionoffandopeningthedoorwiththeheadlighton thealarmsoundsa longbeep 5 AuxiliaryOutput2 NecessárioousodeReléAuxiliar 4 HeadlightWarningOn Off Itisusedtoopenpowerwindows forinstance or withAuxOutput...

Page 16: ...ing on the ignition then activating the brown wire activating the starter motor release the off button aftertheengine startsrunning As the black yellow wire Auxiliary output 3 is in hold mode the ignition will remain on keepingtheenginerunning Toturnofftheengine black yellowwire presstheoffbuttononthecontrolagain WARNING Riskofaccidentsincaseofincorrectinstallation It isnecessarytousesensorsandrelays...

Page 17: ...ons 2nd Beep Turns on the alarm by moving the control away without locking the doors it will onlyturnoffthealarmbypressingthecontrol sOffbutton 3rd Beep Turns the alarm on by pulling the control away and locks the doors it will only turn offthealarmandunlockthedoorsbypressingtheOffbuttononthecontrol 4thBeep Turns the alarm on by pulling the control away and locks the doors Turns off the alarm and unloc...

Page 18: ...ralwearcomponents suchasbattery TARAMPS located at Rua Abílio Daguano 274 Res Manoel Martins Alfredo Marcondes SP ZIP 19 180 000 guaranteesthis product against design manufacturing assembly and or joint and several malfunctions due to design flaws that make it unsuitable or inappropriate for its intended use for a period of 24 months from the dateofpurchase Productsdamagedbyincorrectinstallation w...

Page 19: ...MN_012499_R00 Fabricado por Manufactured by TARAMPS ELECTRONICS LTDA CNPJ TAX ID 11 273 485 0001 03 R João Silvério 121 Res Manoel Martins Alfredo Marcondes SP Indústria Brasileira Made in Brazil ...

Reviews: