2.1 Technical specifications
Mechanism Specifications:
The mechanism is made of hardened aluminum casting, the cams
and locking tabs on the mechanism are made of AISI 304 stainless steel.
Power Source:
All the turnstiles can work with 110/220 VAC. The operating frequencies of the
turnstiles are 50 / 60 Hz.
Internal Voltage:
There is no high voltage in any components except the supply unit in the
turnstile. Depending on the turnstile model, 24/12 VDC internal voltage is measured.
Power Failure and Emergency Mode:
All tripod turnstile models have emergency mode and
are compatible with all types of fire / alarm panels. As soon as the emergency switch is on, the
turnstile guiding indicators blink in the shape of green arrow and give sound warning, the arms are
released in the unlocked position (LTT-3xx-DA) allowing free access. In the case of power failure
in tripod turnstiles, arms run idle or drops in the drop-arm models allowing free access. In drop-
arm models, arm should be lifted to the locked position by hand when the power is back.
Operating Temperature:
Turnstiles can work smoothly in the temperature range between -10
and +70 degrees. It is recommended to use a thermostat heater, optionally, at temperatures lower
than -10 degrees.
Transport and Storage Temperature:
-20 to +80 degrees.
Relative Humidity Ratio:
Maximum 95%.
| 9 |
TECHNICAL
INFORMATION
2