27
Parameter Description
Basic operation in all menus (when navigating the menus via the LCD display)
•
Use ARROW keys to select value or submenu
•
Use ENTER to enter menus or for confirmation, and to activate
•
Use EXIT to step to a higher level or to decline an operation
•
Values are marked with an “ * “ when they can be altered via the ARROW keys
Main Display
The Main Display indicates the position of the monitor (when set up) and the set volume for the monitor.
A “+” symbol indicates that this specific Master Unit has been set up to act as System Controller.
Bass Management †
Bass management is possible in:
- Standard Stereo with 1 Sub
- Standard Stereo with 2 Subs
- All surround modes
The Ellipse monitors utilize 2nd order Hi Pass filters to attenuate frequencies below the set crossover frequency.
The Ellipse TS212 iDP
™
Subwoofer utilises 4th order Low Pass filter to attenuate frequencies above the set crossover
frequency.
• Press ENTER to access the Select Mode
Off - Bass Management is not activated. Only the LFE channel is distributed to the Sub.
Available Crossover Frequencies:
Menu Name
Ellipse Filter
Sub 4th Order
Sub 2nd Order
LFE = Sub
X-Over 50 Hz
50Hz
50Hz
50Hz
No
X-Over 80 Hz
80Hz
80Hz
80Hz
No
Extension 50 Hz
Off
50Hz
50Hz
No
Extension 80 Hz
Off
80Hz
80Hz
No
THX Sim 80 Hz
80Hz
80Hz
Off
Yes
Small Cons 120 Hz ††
120Hz
120Hz
80Hz
Yes
† PC-iP
Via the iDP PC-iP
™
installer package (optional software for the advanced installer) an advanced Bass Management mode
is available. In this mode a greater number of frequencies can be chosen, and all filters (Ellipse HPF, Sub 4th order and
Sub 2nd order) can be controlled to suit demanding & critical setups.
†† Small Cons
- Small Consumer (filter to mimic a small consumer speaker)