background image

12

General Instructions

BATTERY OPTION

Note: Should you choose to run your sensor faucet on battery power, it will require (4) AA 
alkaline batteries.

1.  If the AC adapter is plugged in, unplug it from its power source and the control 
module.

2.  With the help of a phillips head screwdriver, remove the battery cover’s three (3) 

fasteners and pull cover away from the control box.

3.  Replace old batteries if needed.

4.  Install the new AA batteries, making sure that the + and - ends are facing the correct 
direction.  Return the battery cover to its spot and tighten fasteners. 

5.  Re-set the sensor range if needed (see sensor range setup).

TRANSFORMER OPTION 

(Figure 5)

Important: DO NOT plug Transformer into receptacle until all wiring has 
been completed.

This type of Transformer is designed to be plugged into a 120 VAC wall 
receptacle. The Transformer is supplied with a 6 foot Cable.  Remove the 
rubber plug from the transformer connector on the control module.  
Plug the transformer cable into the transformer connector.

plug-in transformer

Figure 5

SENSOR RANGE SETUP

1.  AF-serial sensor range can only be set by using the on/off 
button situated on the bottom right corner of the control box.
Do not attempt to open control box.

2.  Push and hold the on/off  button for 5-7 seconds.  Water fl ow will 

stop and the red LED light inside the electronic eye will blink on.  
Release the on/off  button.  The LED should turn itself off , signaling 
that the faucet is ready for setup.

3.  Place and hold your hand at the desired sensor distance.  The LED 
will turn “ON”.

4.  Use the other hand to press the on/off  button.  The LED will fl ash 
5 times to save the new sensor range setting.

5.  The default sensor range is 5-1/2” (14cm).  Sensing distance is 
adjustable from 3/4” (2cm) to 5-1/2” (14cm).

Note:  For the Hydro Generator (EC-HYDROGEN) power option, refer to the instruction 
manual in the EC-HYDROGEN kit ordered separately.  For hard wiring and hard wire gang-
ing (EC-HARDWIRE) and easy-wire (EC-EASYWIRE) ganging power options , refer to the 
instruction manual in each respective kit when ordered separately.

Summary of Contents for EC-3100 Series

Page 1: ...acement shall be made within a reasonabletimeafterreceiptbyT Softhereturned product ThiswarrantydoesnotcoverItemswhich have received secondary nishing or have been altered or modi ed after purchase or...

Page 2: ...3 2 1 4 5 10 8 6 9 7 Exploded View 2 EC 3100...

Page 3: ...1 2 3 4 6 7 9 8 5 10 Exploded View 3 EC 3101...

Page 4: ...1 3 5 6 7 2 8 4 Exploded View 4 EC 3102...

Page 5: ...1 3 4 5 6 7 2 8 Exploded View 5 EC 3103...

Page 6: ...6 5 4 3 2 1 Exploded View 6 EC 3106...

Page 7: ...male x 1 2 NPSM 5EF 0005 10 Vandal Resistant Key Q015425 45 EC 3102 EC 3103 Electronic Faucets 1 Aerator Vandal Resistant 2 2 GPM 016355 45 2 Angled Sensor w Cable 017195 45 3 Inlet Hose Faucet 1 2 NP...

Page 8: ...Y STOPS Tools Required For Installation of Faucets 8 200mm adjustable wrench 1 8 hex key wrench Basin wrench Slotted screwdriver 3 16 Phillips head screwdriver 1 Pliers Prior to Installation Prior to...

Page 9: ...2A 2B 2C and 2D TO MOUNT ON A SURFACE UP TO 1 25mm THICK Insert faucet cable and spout shank through base gasket and then through the mount ing hole of scrub or wash up sink Secure using lockwasher an...

Page 10: ...asket and into the 9 32 drilled hole Assemble the washer and nut to secure the faucet in place OPTIONAL ANTI ROTATION FEATURE Deck Mount Models EC 3100 EC 3102 Figure 2E Note The anti rotation feature...

Page 11: ...Figure 3 If supplied separately Install mixing valve into fitting on control module as shown in Figure 3 Tighten fitting snugly BUT DO NOT OVERTIGHTEN No thread sealant is necessary Important Orient m...

Page 12: ...the control module Plug the transformer cable into the transformer connector plug in transformer Figure 5 SENSOR RANGE SETUP 1 AF serial sensor range can only be set by using the on off button situate...

Page 13: ...nd conserve its battery power Fresh alkaline batteries should last 450 000 on off cycles 15 seconds 20 minutes 6 presets selectable 0 3 seconds 3 4 to 5 1 2 2 14 cm from sensor AC and or DC Red LED on...

Page 14: ...e manual mixing valve To activate water flow turn the top of the unit counterclockwise 90 clockwise 90 to shut it off To return to sensor mode press the red button and rotate the top of the unit clock...

Page 15: ...to the battery com partment To access the switches remove the 4 screws and back cover of the control module AUTO TIME OUT ADJUSTMENT SWITCHES 1 3 The ChekPoint controller provides six periods to selec...

Page 16: ...troller will enter its lowest scan period of 1 4 seconds When object motion is detected the controller will change the scan period from 0 4 seconds to 0 7 seconds and change back to 0 4 seconds when t...

Page 17: ...distance A About 2 from sensor Q Does the electronic eye require special maintenance A In order for the sensor to function the electronic eye must be clean Use only mild soaps and water Wipe with a s...

Page 18: ...y stop s open if closed 2 Debris in solenoid filter remove clean and reinstall 3 Debris in aerator or spray head remove clean and reinstall 1 Range too long decrease detection zone Check surroundings...

Page 19: ...ngineered plumbing products 2 Saddleback Cove P O Box 1088 T S Brass Europe Travelers Rest SC 29690 De Veenhoeve Phone 864 834 4102 Oude Nieuwveenseweg 84 Fax 864 834 3518 2441 CW Nieuwveen E mail tsb...