11
General Instructions
Mount Control Module to Wall
Install the control module in an appropriate location.
When installed all cables and hoses should have some
slack. Mount control module to wall using mounting
screws and plastic anchors (not included). It is
important to have the control box mounted securely
before any further connections are made.
FOR HOT AND COLD WATER SUPPLY
APPLICATIONS
Supply stops must be furnished by installer or
purchased from T&S. Flush supply lines of any debris.
Tighten compression fi ttings securely on supply lines.
Sensor Cable and Supply Line Connections
(Figures 4, 4a and 4b)
Figure 4
Install Mixing Valve Assembly
(Figure 3)
(If supplied separately)
Install mixing valve into fi tting on control module as
shown in Figure 3. Tighten fi tting snugly
BUT DO NOT
OVERTIGHTEN
. No thread sealant is necessary.
Important: Orient mixing valve as shown in Figure 3.
Figure 3
Figure 4a
Figure 4b
Route the sensor cable from the spout to the top of the control module. Align the (2)
white arrows (one on the male side and one on the female side) and plug the mating
connectors together. Drop the chrome sleeve down over the sensor plug and screw
to tighten (fi g. 4a 1 ). Secure the supply line from the spout to the fi tting on top
of the controller (do not overtighten). (Fig. 4a 2 ) For the EC-3106, also secure the
second supply line to the manual by-pass on the manifold next to the controller (Fig.
4b 3 ). Tighten the compression fi tting securely on the supply lines but do not over
tighten.
1
2
3