Appendix B Fault Symptom Code (FSC) Dictionary
124
Tandberg Data M-Series User’s Guide
2610
FSC_SERVO_FAILED_TO_
GET_CARTRIDGE
The pick action
'completed' with no
cartridge detected in
the hand
2611
FSC_SERVO_FAILED_TO_
OFFLOAD_CARTRIDGE
The put action
'completed' with the
cartridge still in the
hand
2612
FSC_SERVO_
CARTRIDGE_IN_THE_
HAND
Requested action can't
be carried out with a
cartridge in the hand
2613
FSC_SERVO_NO_
CARTRIDGE_IN_THE_
HAND
Requested action can't
be carried out without
a cartridge in the hand
2614
FSC_SERVO_AXIS_NOT_
INITIALIZED
Command cannot be
executed without first
initializing the axis
2615
FSC_SERVO_NVR_
THETA_DATA_INVALID
Theta NVR data has
been corrupted, or not
yet initialized
2616
FSC_SERVO_NVR_
FRICTION_DATA_
INVALID
Axis friction NVR data
has been corrupted, or
not yet initialized
2617
FSC_SERVO_NVR_
OFFSET_DATA_INVALID
Axis offset NVR data
has been corrupted
2618
FSC_SERVO_NVR_
BUILD_DATA_INVALID
The build level NVR
data has been
corrupted, or not
initialized
2619
FSC_SERVO_NVR_DATA_
INVALID
An error has been
detected in the servo
NVR
FSC
Name
Description
FRU Name
Confidence %
Summary of Contents for MSERIES USER
Page 1: ...Tandberg Data M Series User s Guide T6423045 03 A01 ...
Page 10: ...Figures x Tandberg Data M Series User s Guide ...
Page 12: ...Tables xii Tandberg Data M Series User s Guide ...
Page 16: ...Preface xvi Tandberg Data M Series User s Guide ...
Page 28: ...Chapter 1 Overview Library Features 12 Tandberg Data M Series User s Guide ...
Page 122: ...Appendix A Specifications SCSI Specifications 106 Tandberg Data M Series User s Guide ...
Page 190: ...Index 174 Tandberg Data M Series User s Guide ...