Appendix

 

TANBead Nucleic Acid Extraction System Maelstrom 8 Autostage (non-sterile)

 

 

19.1

 

Intended Use:

 

 

 

The  M8-H  Autostage  can  be  used  in  combination  with  the  Maelstrom  8  and 
TANBead’s Nucleic Acid Extraction Kits to extract DNA/RNA from samples.

 

 

The  M8-H  Autostage  can  hold  the  Maelstrom  8  for  a  stable,  precise,  and 
automated operation.

 

 

Safety and EMC Information:

 

Safety Requirements

 

 

The medical device has passed the tests and conformed to the standards of EN 
61010-1: 2001, “Safety requirements for electrical equipment for measurement, 
control, and laboratory use - Part 1: General requirements”.

 

 

The medical device has passed the tests and conformed to the standards of EN 
61010-2-101:  2002  “Safety  requirements  for  electrical  equipment  for 
measurement, control and laboratory use - Part 2-101: Particular requirements 
for in vitro diagnostic (IVD) medical equipment”.

 

 
 

EMC Requirements

 

 

The medical device has passed the tests and conformed to the standards of IEC 
61326-1:2012 & IEC 61236-2-6:2012, “Electrical equipment for measurement, 
control  and  laboratory  use  -  EMC  requirements  -  Part  2-6:  Particular 
requirements - In vitro diagnostic (IVD) medical equipment”.

 

 

The medical device has passed the tests and conformed to following standards:

 

EN 61326-1: 2013

 

EN 61326-2-6:2013

 

IEC 61000

 

EN 55011:2016

 

 

 

 

 

Summary of Contents for Maelstrom 8 Autostage

Page 1: ...Magnetic Rotary Mixer Maelstrom 8 channel Handler...

Page 2: ...s 7 6 Before Usage 8 7 Switch on or off 9 8 Main Page 10 9 Functional Keys 11 10 Guide Mode 13 11 Manual Mode 15 12 Edit Page 16 To edit the protocol on the M8 H 16 To edit the protocol in computer 19...

Page 3: ...1 About This Manual The label on the instrument the User manual and other packaging material may contain the following symbols...

Page 4: ...accomplish any application of magnetics beads Please read this manual carefully before usage NOTE Low battery level of the M8 H might cause the interruption of experiments Specifications Model Maelstr...

Page 5: ...irements The medical device has passed the tests and conformed to the standards of IEC 61010 1 2010 Safety requirements for electrical equipment for measurement control and laboratory use Part 1 Gener...

Page 6: ...4 2 Equipment List...

Page 7: ...5 3 Overview...

Page 8: ...6...

Page 9: ...might cause a hazard Please contact technical support in case of higher sound pressure level This device can be hazardous due to the use of chemical and biohazardous substances Users should adhere to...

Page 10: ...E The automatic turn on only happens at first charging 4 When the M8 H is plugged into charging port the charging indicator on the screen will turn orange Fig 4 After the M8 H is fully charged it will...

Page 11: ...9 7 Switch on or off Press menu button to switch on the M8 H To turn off press menu button for 3 seconds M R M R ON Press menu button M OFF Press menu button M for 3 seconds M R...

Page 12: ...oose to operate the M8 H in Guide mode or Manual mode To pre set or edit program please enter edit page To set up system beep sound auto off time and date please enter the setting page Further system...

Page 13: ...g menu button twice 3 In Guide mode user can exit program by pressing menu button twice Rod Button 1 In manual mode press rod button to extend the magnetic rods To withdraw the magnetic rod just press...

Page 14: ...enter mixing trigger to select The Enter Mixing Trigger 1 Press enter mixing trigger to activate the enter function 2 In guide mode press enter mixing trigger to start the chosen program 3 During the...

Page 15: ...ess enter mixing trigger to proceed There are pre installed programs in the M8 H Use click wheel and enter mixing trigger to select About editing the program Please refer to the instructions of edit p...

Page 16: ...well The beads will be collected on to the spin tips Vapor After the beads in well are complete collected on the spin tips raise the M8 H off the wells and sit the beads in the air for vaporing Pause...

Page 17: ...t and right keys to change the spin direction Collection 1 When mixing stopped raise the M8 H off the wells and press rod button to extend magnetic rods 2 After the rods are completely extended slowly...

Page 18: ...the M8 H Autostage To edit the protocol on the M8 H Select the target program User can edit delete or copy the program Program number User can store maximum 50 programs 01 50 Well capacity The volume...

Page 19: ...ell to set the specific action When it is connected with the M8 H Autostage the M8 H can process maximum 12 columns of wells Mode Performable actions Mixing define Well Time Stir RPM Temperature Enabl...

Page 20: ...mixing trigger to enter 6 Use left and right keys of click wheel to move the cursor 7 Use up and down keys of click wheel to adjust the factor 8 Set the step at Step field 9 Set the action at Mode fie...

Page 21: ...program copy and paste one of the files and rename it in numbers 1 50 The Layout of programming protocols in an Excel file Program name The program name is stored in A1 field of the spreadsheet Maxim...

Page 22: ...d Operation time of each action 3599 is the maximum value CW CCW second Frequency of rotation change Input value from 0 990 Number 20 means the spin direction will change every 20 seconds Equivalent t...

Page 23: ...n of hardware and software and S N number of the M8 H If the detailed setting information before shipping is needed please contact manufacturer Time Setting User can use left and right keys of click w...

Page 24: ...ep sound and adjust LCD backlight Click on Apply button to save the setting System Param Setting User can use left and right keys of click wheel to move the cursor NOTE 1 About Stand Connection Please...

Page 25: ...ery power remains less than 10 Red Yes Please charge the M8 H with cable or mini USB 3 In the boot state the voltage is less than 2V when the M8 H is charging Yellow No Please contact technical suppor...

Page 26: ...technical support 6 DC motor is blocked No No 1 Reboot 2 If it happens again please contact technical support 7 Step motor is over current No No 1 Reboot 2 If it happens again please contact technica...

Page 27: ...cleaned To clean the magnetic rods wipe with a soft cloth dampened with 70 ethanol If the magnetic rods cannot be cleaned please contact your local distributor or manufacturer TANBead for technical a...

Page 28: ...26 17 Patents Patents USA US09616398B2 EU EP2937136 Canada CA2862946 Japan JP6151735 Korea 10 1696517 WIPO WO2016127292 China CN104971638B Taiwan I526245...

Page 29: ...ostage provides a walk away solution for the M8 H With this automated platform all extraction functions for handling magnetic beads are comprehensively coordinated including mixing collection transfer...

Page 30: ...control and laboratory use Part 1 General requirements The medical device has passed the tests and conformed to the standards of EN 61010 2 101 2002 Safety requirements for electrical equipment for me...

Page 31: ...29 19 2 Equipment List NOTE The function of the transmission cable combines with charging for the M8 H and software communication between the M8 H and the M8 H Autostage...

Page 32: ...30 19 3 Overview Main operation interface Power input...

Page 33: ...stage does not exceed 80 dB and so does not cause a hazard Please contact technical support in case of a higher sound pressure level This device can be hazardous due to the use of chemical and biohaza...

Page 34: ...ansmission cable 3 Set enable connection on the M8 H 4 Place the 96 well plate on the slider and checking the relative position If further assistance is required please contact your local distributor...

Page 35: ...h for the heated carriage plate the power button is the switch for the M8 H Autostage excluding the heating function 19 9 Standby Mode After resetting or finishing the program the Autostage will stay...

Page 36: ...iage plate can be to set up in the M8 H The maximum temperature is 70 19 11 Emergency Mode Pushing the emergency stop can stop running the M8 H Autostage immediately and alert with a warning tone Plea...

Page 37: ...ion to perform elution directly in PCR tubes With the adaptor of the 8 strip PCR tube the elution can be performed in the 8 strip PCR tube directly User can switch the height setting for elution in de...

Page 38: ...amage or contamination of the samples Wear gloves and appropriate personal protective equipment If the device is used with biohazardous materials dispose of any cleaning materials used in accordance w...

Page 39: ...ntry please contact your supplier if necessary Please follow your institutional and country specific requirements to handle the disposal of accessories Device must be decontaminated prior to disposal...

Page 40: ...V2 0 10F No 95 Xinpu 6th St Taoyuan Dist Taoyuan City 330 Taiwan R O C Tel 886 3 3167568 Fax 886 3 3173369...