English
RCD-2
Programming the detectors´ addresses
Name of CVs
CV
no.
Input value
(Default
value)
Remarks and tips
Address
detector 1
1
or
9
1 ... 24
(1)
Address of detector 1 in the
RailCom data bus.
CV#9 = alternative CV
Address
detector 2
2
1 ... 24
(2)
Address of detector 2 in the
RailCom data bus
Reading-out the CVs of the RCD-2
Name of CVs
CV
no.
Input value
(Default
value)
Remarks and tips
CV-request
for
CV #1-199
6
1 ... 199
The set CV values can be shown
only when the detector(s) has /
have been assigned to a display
module. In CV#6 you can enter
directly the CV numbers between
1 and 199 to be read out.
CV-request
for
CV #200-289
7
0 ... 89
For the CV numbers between 200
and 289 enter in CV #7 the
number without the hundred-
value (e.g. for # 248 value 48)
Performing a reset
Name of CVs
CV
no.
Input value
(Default
value)
Remarks and tips
Reset
8
1 ... 255
By entering any value all settings
are restored to the values in state
of delivery.
Page 30
tams
elektronik