Allocation of the outputs to further locomotive addresses
In order to allocate further outputs to the detectors and the locomotive
address groups proceed as described in the section before.
Name of CVs CV no.
Remarks and tips
Allocation of
the outputs
to the
detectors
and
locomotive
addresses
44 and 46
Detector 2 / locomotive address group 1
54 and 56
Detector 1 / locomotive address group 2
64 and 66
Detector 2 / locomotive address group 2
...
...
274 and 276 Detector 1 / locomotive address group 13
284 and 286 Detector 2 / locomotive address group 13
Setting the switching times of the outputs
Name of CVs CV no.
Input value
(Default
value)
Remarks and tips
Switching
times of the
outputs
By setting the switching time you determine how long
the output is supplied with current. Increasing the
input value by 1 prolongs the switching time by 65,5
msec. The longest switching time to be set is 16,5 sec.
10
1 ... 255 (4)
output 1
11
1 ... 255 (4)
output 2
12
1 ... 255 (4)
output 3
...
...
17 or 3 1 ... 255 (4)
output 8
CV#3 = alternative CV