5.9. Settings for analogue mode
Name
No.
Input values
(Default)
Remarks and tips
Functions
active in
analogue
mode
(F1 to F8)
13
0 … 255
(0)
F1 on
1
F2 on
2
F3 on
4
F4 on
8
F5 on
16
F6 on
32
F7 on
64
F8 on
128
Functions
active in
analogue
mode
(F0, F9 to F12)
14
0 … 31
(0)
F0 on
1
F9 on
2
F10 on
4
F11 on
8
F12 on
16
Reaction to
overvoltage pulses
(analogue
alternating current
systems)
64
0 ... 255 (50)
= Sensitivity with which the decoder reacts
to an overvoltage pulse with a change of
direction.
0 = highest sensitivity
255 = lowest sensitivity
Tip: If the sensitivity is set too high, the decoder reacts to interference voltages from the system with a
change of direction. If it is set too low, it does not react to the changeover impulse.
Configuration variables and registers | 55