tams elektronik
!
English
LD-G-32.2 and LD-W-32.2
In order to connect decoders without interface or soldered connecting
wires you will need wire. Recommended cross sections:
> 0,04 mm² for the connections to the function outputs;
> 0,05 mm² for the connections to the motor and current collectors.
If you want to connect a decoder LD-
G
-32.2 to an a.c. motor you need:
a load control adapter LRA (item no. 70-02105 or 70-02106) or
a permanent magnet (e.g. item no. 70-04100, 70-04200 or 70-
04300) or
a motor modification set (e.g. item no. 70-40110, 70-40210 or 70-
40310).
In order to bridge short current interruptions you need:
an electrolytic capacitor with a capacity of 100 to 470 µF and a
proof voltage of minimum 35 V.
2. Safety instructions
Caution:
Integrated circuits (ICs) are inserted on the decoder. They are
sensitive to static electricity. Do not touch components without first
discharging yourself. Touching a radiator or other grounded metal part
will discharge you.
Mechanical hazards
Cut wires can have sharp ends and can cause serious injuries. Watch
out for sharp edges when you pick up the PCB.
Visibly damaged parts can cause unpredictable danger. Do not use
damaged parts: recycle and replace them with new ones.
Page 6