![tams elektronik LD-G-32.2 Manual Download Page 36](http://html1.mh-extra.com/html/tams-elektronik/ld-g-32-2/ld-g-32-2_manual_3571089036.webp)
tams elektronik
English
LD-G-32.2 and LD-W-32.2
Setting the load control (LD-G-32.2 only)
Name of CVs /
registers
CV-
no.
Rg-
no.
Input value
(Default)
Remarks and Tips
Parameter of
load control KP
50
23
0 ... 255 (90)
= Proportional component
of the load control.
The parameter KP defines the basic speed. A too small value
à
locomotive too slow. A too
high value
à
heavy shuttering of the locomotive.
Parameter of
load control KI
51
24
0 ... 255 (70)
= Integral component of
the load control.
The parameter KI provides the fine tuning of the load control. The value has to be adjusted in
very small steps. A too high value
à
heavy shuttering of the locomotive.
Parameter of
load control KD
52
25
0 ... 255 (40)
= Differential component of
the load control.
The parameter KD retards the transforming of the load control. A too small value
à
shuttering of the locomotive. A too high value
à
rocking of the locomotive.
Optimising the
load control
124 60
1...15 (4)
To adjust the load control to
the individual motor voltage
The value for CV 124 has to be altered when the velocity does not increase with the high
speed levels. Alter the value for CV 124 step by step until the highest velocity has just been
reached at the highest speed level.
Page 36