background image

                                                                                                                             

Installation Manual

Ground Roof

Mount Series

[email protected]            1-800-819-7236 Ext 556

     Page 9

Step 3:  Attach Pre-Assembled Panel array to footings.

A. Loosely attach one end of the Panel assembly to the U-feet on the footings. 

Step 4:  Attach rear braces to panel supports

A.

Tilt up the array, and the rear braces, and bolt the rear leg into the hole chosen at the distance on 

step 2

of “Determine

foot spacing

” operation, or the general spec chart.

B.

Torque all locations to 132 in-lbs.

Summary of Contents for Ground Roof Mount Series

Page 1: ...d Roof Mount Series Installation Manual Panel Support length 90 UNI GR Manual v3 Formodels UNI GR 90 UNI GR 130 130 The picture at rtight shows the rear view of 2 of the UNI GR mounts connected with t...

Page 2: ...ion 10 InstallerResponsibility 11 Warranty Information 11 Introduction The Universal Ground Roof Mount is a simple and universal mounting solution up to 3 solar panels With its user adjustable angle s...

Page 3: ...nnector 2 2 51 0545 001 Panel Support Channel 45 inch 4 51 0565 001 Panel Support Channel 65 inch 4 51 0546 000 Inner Brace Channel 46 inch 2 2 51 0546 001 Outer Brace Channel 46 inch 2 2 51 6000 003...

Page 4: ...t Panel Support Channels A Slide the 10 connector halfway into the end of the one of the panel support and install the 5 16 hardware Torque to 132 in lbs repeat with the second panel support to achiev...

Page 5: ...rface measure the center to center distance between the U feet to determine the front to rear spacing for the footing B Keep the rear brace assembled at the overlap determined in prior operation preas...

Page 6: ...nd D is the distance from the top of the module mounting rail to the hole used to connect the back leg See the diagrams on Page 4 UNI GR 90 UNI GR 130 A ANGLE 36 A ANGLE 32 C OVERLAP 16 28 40 44 C OVE...

Page 7: ...Installation Manual Ground Roof Mount Series support tamaracksolar com 1 800 819 7236 Ext 556 Page 6 Step 3 Foot attaching options Use Galvanized or Stainless Steel Hardware See Suggestions below...

Page 8: ...d supports parallel C Align mounting holes on the panels with the slots on the panel supports allow Approximately 1 4 to 1 in between PV modules and leave any available left over support length at the...

Page 9: ...otings align the feet east west and north south and torque 3 8 16 galvanized hardware to 16 ft Lbs Concrete footings shown Space between mounts Step 2 Attach Preassembled rear braces to footings A Loo...

Page 10: ...to footings A Loosely attach one end of the Panel assembly to the U feet on the footings Step 4 Attach rear braces to panel supports A Tilt up the array and the rear braces and bolt the rear leg into...

Page 11: ...nt This brace is adjustable from 18 25 to 32 and can be used with solar panels that have mounting holes that at between 7 and 15 from the end of the modules A Loosely connect the inner and outer inter...

Page 12: ...s VOID if the practices specified by AAMA 609 610 02 Cleaning and Maintenance for Architecturally Finished Aluminum www aamanet org are not followed by Purchaser for Tamarack Solar s aluminum based pr...