INSTALLATION 

OPERATION  

MAINTENANCE 

                       MANUAL 
AE-Series, MSC-Series 

Solar Collectors 

 

 

 

 

 

 
 
 
 

Alternate Energy Technologies, LLC.

 

1345 Energy Cove Court  · Green Cove Springs, FL  32043 

PH: 800-874-2190  ·  Fax: 904-529-9837  ·  Email: [email protected] 

 
 

Summary of Contents for AE-Series

Page 1: ...ON OPERATION MAINTENANCE MANUAL AE Series MSC Series Solar Collectors Alternate Energy Technologies LLC 1345 Energy Cove Court Green Cove Springs FL 32043 PH 800 874 2190 Fax 904 529 9837 Email info aetsolar com ...

Page 2: ... this page left blank intentionally ...

Page 3: ...ector in the Northern Hemisphere is optimized when the collector is mounted facing true south Figure 1 Performance however suffers very little when the collector is oriented no more than 45 East or West of True South The collector should be un shaded by any permanent obstacle between 9 00 a m and 3 00 p m on any day of the year Figure 1 Collector Tilt Optimal annual efficiency is achieved by tilti...

Page 4: ...233 100 233 124 233 xx FM MSC RRM 88 663 100 663 80 663 88 663 100 663 122 663 87 375 99 375 79 375 87 375 99 375 12 375 xx RM MSC RM 86 835 98 835 78 835 86 835 98 835 122 835 87 333 99 333 79 333 87 333 99 333 123 333 Dimensions shown length width and height are nominal and listed in inches area in ft and weight in lbs Use the formulas below for tilted applications To calculate the length of the...

Page 5: ...the collector directly or parallel to a flat roof surface Use the universal tilt mount kit and 1 aluminum square tube to rack the collector to the proper angle The collector should be mounted as close to the storage tank as possible to minimize heat loss in the piping runs If the home has limited attic access mounting the collectors nearer the roof peak provides for additional attic workspace The ...

Page 6: ...er for sealing roof penetrations Henry Co 204 208 or 209 roof mastic or Dow Corning Glazing Sealant also are acceptable sealants If the region is subject to high wind or hurricane conditions additional steps may be required to secure the collector and mounting hardware to the structural members In certain areas of the country local building codes may require collector wind load testing or prescrib...

Page 7: ...zontal and vertical piping may not reduce the performance or rating of any structural member or fire rated assembly Adhere to all applicable local codes and ordinances This solar collector is leak tested at the factory Once the collector has been installed as part of a domestic solar water heating system the system should be filled pressurized and checked for leaks Repairs should be corrected and ...

Page 8: ...s or under stagnation conditions can melt this type of material Any above ground exterior pipe insulation is subject to ultra violet UV degradation and must be wrapped with foil tape or painted with two coats of high quality water based acrylic resin coating as supplied by the insulation manufacturer Rubatex UV Protective Coating or its equal is the required coating material Collector Sensor Place...

Page 9: ...uctor type The wiring should be PVC insulated with a PVC UV rated gray jacket suitable for exterior use Use Eastman Wire Cable No 5704 Belden Wire and Cable No 8461 or equivalent This completes the system installation procedure Collector Maintenance Collectors operate best when the glass is clean and unobstructed If they become dirty wash them with mild soapy water and rinse Remove any branches or...

Page 10: ...sorber plate high frequency forge welded to create a crystalline homogenous connection between the fin and riser tube Absorber Coating Exclusively by Thermafin Manufacturing Selective Crystal Clear Coating α 0 96 ε 0 08 Glazing Low Iron Tempered Glass exclusively using our new High T tempered glass with a total solar energy transmission of 90 Gasket Grommets A UV durable EPDM U channel gasket with...

Page 11: ...0 0 9397 0 3640 66 0 0 9135 0 4067 2 2460 21 0 0 3584 0 9336 0 3839 67 0 0 9205 0 3907 2 3559 22 0 0 3746 0 9272 0 4040 68 0 0 9272 0 3746 2 4751 23 0 0 3907 0 9205 0 4245 69 0 0 9336 0 3584 2 6051 24 0 0 4067 0 9135 0 4452 70 0 0 9397 0 3420 2 7475 25 0 0 4226 0 9063 0 4663 71 0 0 9455 0 3256 2 9042 26 0 0 4384 0 8988 0 4877 72 0 0 9511 0 3090 3 0777 27 0 0 4540 0 8910 0 5095 73 0 0 9563 0 2924 3...

Page 12: ...Alternate Energy Technologies LLC 1345 Energy Cove Ct Green Cove Springs FL 32043 PH 800 874 2190 FAX 904 529 9837 www aetsolar com info aetsolar com Document MAN COL SRCC2013xxx v1 ...