background image

 

Area of Rescue Command Unit

 

Installation Guide 

Model AOR-5 / Model AOR-10

 

Page 

6

 of 

23

 

 

  Rev. 4/13/2022

 

 

Copyright 2022 Talk-A-Phone, LLC

 

• 7530 North Natchez Avenue • Niles, Illinois 60714 • Phone 773.539.1100 • [email protected] • www.talkaphone.com.  

 

All prices and specifications are subject to change without notice. Talk-A-Phone, Talkaphone, bAlert, Scream Alert, WEBS, and WEBS Contact are registered trademarks of 
Talk-A-Phone, LLC.  All rights reserved.  All other trademarks mentioned in this document or website are the property of their respective owners and does not imply or indicate 
any approval, endorsement, sponsorship, or affiliation with such owners unless such approval, endorsement, sponsorship, or affiliation is expressly indicated. 

VI. 

Installation 

1. 

Remove the 

AOR-5 / AOR-10 

unit from its packaging carton and inspect for any possible 

damage.  If the unit is damaged or if any components are missing, please contact your 
Talkaphone distributor immediately. 

Do not discard any hardware or packaging prior to checking for all included components listed 
above and ensuring that the unit is installed and functioning as expected. 

2.  Model Configurations without Latched Door:

 

Remove the six (6) screws from the stainless steel front panel.  Carefully take the panel off the 
enclosure

—there are cables connected to the front panel. 

Model Configurations with Latched Door:

 

Open the latched door and remove the packaged front cover door handle.  Install the handle onto 
the outside surface of the latched door using the provided screws. 

Remove the six (6) screws from the stainless steel front panel.  Carefully take the panel off the 
enclosure

—there are cables connected to the front panel. 

3. 

The 

AOR-5 / AOR-10 

unit may be either surface mounted or flush mounted to a wall. 

 

NOTE:

 For flush mounting configuration without the latched door, 

AOR-5 / AOR-10 

units 

should be ordered with the available 

AOR-TR10

 Flush Mount Trim Ring (sold 

separately). 
 
For flush mounting configurations with latched door, 

AOR-5 / AOR-10 

units should be 

ordered with the available 

AOR-TR10-D

 Flush Mount Trim Ring (sold separately). 

 
 

NOTE:

 Conduit knockouts exist on the left, right, and bottom sides of the cabinet for 

access to power and communication lines.  Determine the method of bringing in these 
power and communication lines 

before

 mounting the enclosure. 

 

NOTE:

 Whenever possible, it is best to keep the maximum clearance possible between 

analog phone lines and alternating current.  Running phone lines too close to hot VAC 
lines will lead to noise or interference on the phone line. 

 

4.  Surface Mounting onto an Interior Wall:

 

The 

AOR-5 / AOR-10 

unit has four (4) surface mounting keyholes located on the rear of the 

chassis. 

5.  Flush Mounting into an Interior Wall:

 

 

The 

AOR-5 / AOR-10 

unit has six (6) screw points on the sides which can be used to mount the 

Command Unit within a wall. 

Both halves of the 

AOR-TR10

 trim ring (or 

AOR-TR10-D 

for latched door configurations) should 

be secured to the wall using the provided 6-18 screws. 

 

 

Summary of Contents for AOR-5

Page 1: ...tion or programming of Talkaphone Area of Rescue Call Stations please refer to the manual for the AOR CSE Analog Call Station It is recommended that this instruction set be read completely prior to th...

Page 2: ...ifications Twisted shielded pair specifically designed for use with analog telephones Connect shield to earth ground at the Command Unit Distance ranges for recommended wire gauges are provided in the...

Page 3: ...sorship or affiliation is expressly indicated IV System Overview 1 Local Mode In Local Mode pressing the button on any of the Talkaphone Analog Call Stations will call the AOR 5 AOR 10 Command Unit an...

Page 4: ...rs and does not imply or indicate any approval endorsement sponsorship or affiliation with such owners unless such approval endorsement sponsorship or affiliation is expressly indicated V Internal Sys...

Page 5: ...pective owners and does not imply or indicate any approval endorsement sponsorship or affiliation with such owners unless such approval endorsement sponsorship or affiliation is expressly indicated Fi...

Page 6: ...move the packaged front cover door handle Install the handle onto the outside surface of the latched door using the provided screws Remove the six 6 screws from the stainless steel front panel Careful...

Page 7: ...of the Command Unit Always try to separate power lines from communication lines in order to mitigate the risks of noise or interference on the communication lines A B C D This section outlines the int...

Page 8: ...ating PSTN POTS Telephone Line for Off site Dialing If an analog PSTN POTS telephone line or analog PBX extension line is to be used for off site dialing terminate the analog telephone line or PBX ext...

Page 9: ...E Stations and PSTN Line Carrying out this procedure on the controller board is required for proper open short fault and PSTN POTS telephone line fault detection on the system In the lower right of th...

Page 10: ...d programming to factory defaults Requires prior Master Access Code entry 32 up to 8 digits Programs and stores a new Master Access Code Requires prior Master Access Code entry 33 up to 8 digits Progr...

Page 11: ...or 1 10 Does not require Guard Access Code or Master Access Code entry 4 AOR CSE Station all call when connected through a Sub Command Unit or a remote PSTN call Does not require Guard Access Code or...

Page 12: ...beeps or silence re enter the programming code again If you continue to hear two 2 beeps or silence a second time hang up and try again 3 Remote Mode 1 Pick up a Sub Command Unit handset or remotely c...

Page 13: ...his document or website are the property of their respective owners and does not imply or indicate any approval endorsement sponsorship or affiliation with such owners unless such approval endorsement...

Page 14: ...E Station 4 1 through 5 or 1 through 0 There will be a short pause and then the AOR CSE Station will answer with an open channel microphone and speaker are active 2 Enter the security code 827827 or T...

Page 15: ...website are the property of their respective owners and does not imply or indicate any approval endorsement sponsorship or affiliation with such owners unless such approval endorsement sponsorship or...

Page 16: ...autodial phone number 0 20 digits 03 Fourth autodial phone number 0 20 digits 04 Fifth autodial phone number 6 digits 18 Timing dialing options For further details see Timing Dialing Options for the A...

Page 17: ...r Function Values Definition A Talk Listen Delay Switching time between talk and listen modes i e VOX switching time 1 0 1 seconds 2 0 2 seconds Default 3 0 3 seconds 4 0 4 seconds 5 0 5 seconds 6 0 6...

Page 18: ...ndicating which AOR CSE Station is calling in If a call is already in progress any other calls which come in will cause the appropriate LED to blink to indicate they are awaiting an open line if recor...

Page 19: ...set 3 A prerecorded voice message with physical location information may play at the beginning of the call 4 Answering Calls at a Sub Command Unit 1 When calls are routed to a Sub Command Unit the Sub...

Page 20: ...h on the Command Unit panel f Visual Indicator for Battery Fault When a battery fault occurs at the Command Unit the BATTERY FAULT LED will flash on the Command Unit panel g Visual Indicator for Power...

Page 21: ...ip or affiliation is expressly indicated 5 Primary Power Loss When the Command Unit loses primary power and begins to run on battery backup the POWER LED will disengage or turn off on the Command Unit...

Page 22: ...requires a dedicated telephone line 3 If I forgot the Master Access Code or the programming configuration can I reset the programming on the Command Unit If you have forgotten your Master Access Code...

Page 23: ...may not have been properly terminated inside the Command Unit Verify the internal connections 3 The cabling for the PSTN POTS telephone line or analog PBX extension line may have been disconnected Pl...

Reviews: