VI.
Installation
1.
Remove the
AOR-5 / AOR-10
unit from its packaging carton and inspect for any possible
damage. If the unit is damaged or if any components are missing, please contact your
Talkaphone distributor immediately.
Do not discard any hardware or packaging prior to checking for all included components listed
above and ensuring that the unit is installed and functioning as expected.
2. Model Configurations without Latched Door:
Remove the six (6) screws from the stainless steel front panel. Carefully take the panel off the
enclosure
—there are cables connected to the front panel.
Model Configurations with Latched Door:
Open the latched door and remove the packaged front cover door handle. Install the handle onto
the outside surface of the latched door using the provided screws.
Remove the six (6) screws from the stainless steel front panel. Carefully take the panel off the
enclosure
—there are cables connected to the front panel.
3.
The
AOR-5 / AOR-10
unit may be either surface mounted or flush mounted to a wall.
NOTE:
For flush mounting configuration without the latched door,
AOR-5 / AOR-10
units
should be ordered with the available
AOR-TR10
Flush Mount Trim Ring (sold
separately).
For flush mounting configurations with latched door,
AOR-5 / AOR-10
units should be
ordered with the available
AOR-TR10-D
Flush Mount Trim Ring (sold separately).
NOTE:
Conduit knockouts exist on the left, right, and bottom sides of the cabinet for
access to power and communication lines. Determine the method of bringing in these
power and communication lines
before
mounting the enclosure.
NOTE:
Whenever possible, it is best to keep the maximum clearance possible between
analog phone lines and alternating current. Running phone lines too close to hot VAC
lines will lead to noise or interference on the phone line.
4. Surface Mounting onto an Interior Wall:
The
AOR-5 / AOR-10
unit has four (4) surface mounting keyholes located on the rear of the
chassis.
5. Flush Mounting into an Interior Wall:
The
AOR-5 / AOR-10
unit has six (6) screw points on the sides which can be used to mount the
Command Unit within a wall.
Both halves of the
AOR-TR10
trim ring (or
AOR-TR10-D
for latched door configurations) should
be secured to the wall using the provided 6-18 screws.