Unit trouble : Monitoring inner circuit and wiring damage
Operation : Trouble alarm
Low voltage trouble : Monitoring low voltage
Operation : Trouble alarm
Positioning trouble : Monitoring failure to replace view finder
Operation : Trouble alarm
Limited Warranty :
TAKEX products are warranted to be free from defects in material and workmanship for 12 months from original date of shipment. Our warranty does not cover damage
or failure caused by natural disasters, abuse, misuse, abnormal usage, faulty installation, improper maintenance or any repairs other than those provided by TAKEX. All
implied warranties with respect to TAKEX, including implied warranties for merchantability and implied warranties for fitness, are limited in duration to 12 months from
original date of shipment. During the Warranty Period, TAKEX will repair or replace, at its sole option, free of charge, any defective parts returned prepaid. Please provide
the model number of the products, original date of shipment and nature of difficulty being experienced. There will be charges rendered for product repairs made after our
Warranty Period has expired.
In Japan
Takex America Inc.
4/15 Howleys Road, Notting Hill,
VIC, 3168
Tel : +61 (03) 9544-2477
Fax : +61 (03) 9543-2342
Takenaka Engineering Co., Ltd.
83-1, Gojo-sotokan,
Higashino, Yamashina-ku,
Kyoto 607-8156, Japan
Tel : 81-75-501-6651
Fax : 81-75-593-3816
http : // www. takex-eng. co. jp /
Takex America Inc.
151 San Zeno Way
Sunnyvale,
CA 94086, U.S.A
Tel : 408-747-0100
Fax : 408-734-1100
http : // www. takex. com
Takex Europe Ltd.
Aviary Court, Wade Road,
Basingstoke, Hampshire. RG24 8PE, U.K.
Tel : (+44) 01256-475555
Fax : (+44) 01256-466268
http : // www. takex. com
In the U.S.
In the U.K.
In Australia
Passive infrared sensor
PA-4810E
PA-4820E
Passive infrared (QUAD)
72 (18 pairs)
24 (6 pairs)
9.5 to 28V DC (non-polarity)
3min. -Flickering, 47min. -Lighting
Sensitive zone : 36 pairs
Sensitive zone : 12 pairs
Indoor (wall / pillar)
Terminals
5.82oz (165g)
resin (White)
Model
Detection system
Coverage
Sensitive zone
Supply voltage
Current consumption
Alarm output
Tamper output
Alarm memory
Fine motion detection
LED (Red)
Trouble signal
Ambient temperature
range
Mounting position
Wiring connections
Weight
Appearance
Adjustment range
10
SPECIFICATIONS
The specifications are subject to change without notice.
25mA Max. (N.C./N.O. contact)
Dry contact (Semi-Conductor)
Reset : Approx. 2 sec. (N.C./N.O. selectable)
30V DC (24V AC) 0.25A Max. (protective resistor 3.3
Ω
)
Dry contact (type N.C.)
Open when cover is detached
30V DC 0.1A Max.
Alarm LED
Flickering (every 0.5 sec.) : Warming-up
Lighting (approx.2sec.) : Alarm
Flickering (every 0.25 sec.) : Trouble indication
Continuous lighting
: Trouble alarm
(Disabled is LED except trouble indicaiton)
Memory LED Flickering : Memory activated
Lighting : Memory indicated
+
14°F to
+
122°F (without dewdrops)
(
−
10°C to
+
50°C)
Vertically 20° Horizontally
±
5°
Wide angle protection
40' (12m) Max.
Long range protection
82' (25m) Max.
Mounting hole
11
EXTERNAL DIMENSIONS
3.54" (90mm)
5" (127mm)
2.36" (60mm)
P.C.D. 3.29" (83.5mm)
P.C.D. 3" (76mm)
CORNER MOUNTING HOLE
4 CORNERS (KNOCKOUT)
WALL MOUNTING
HOLE
(KNOCKOUT)
WIRING HOLE
(KNOCKOUT)
WIRING HOLE
(KNOCKOUT)
2021.8.26