Operation LED blinks for about 1 min after supplying power.
The unit doesn’t operate for this time as it is the sensor
stabilising period.

The number of counts can be selected according to the
environmental conditions.

* MS-12FE has two sets of above switches upper and lower 

sensor.

Alarm is triggered only when surrounding environment is
darker than the illuminance setting.

Warm up period

Contact output selectable

Detection mode 

[Only applicable to MS-12FE]

Pulse count selectable

Sensitivity adjustment

LED ON/OFF selectable switch

Day Light

Operation time can be adjusted between 2sec. and to 5min.
approx.

Delay time

ON

OFF

ON

OFF

[Factory set]

ON

1a

1b

OFF

a (N.O)

b (N.C)

[Factory set]

Less sensitive, prevents false alarms
caused by temperature fluctuation.

More sensitive

ON

OFF

ON

OFF

[Factory set]

Lights at alarm

LED disabled. (During warm up
period, light flickers.)

ON

OFF

AND

OR

[Factory set]

Alarm signal is issued only when
both upper and lower sensors detect
objects simultaneously.

Alarm signal is issued when either
upper or lower sensors detect
objects.

The unit operates during night time only.

The unit operates day and night. 
(Factory set)

Sensitivity can be adjusted between 30% (L)
and 170%(H).
[Factory set:100%]

Operation time can be adjusted between
2sec. and 5min. approx.
[Factory set : 2sec]

H

L

NIGHT

DAY &
NIGHT

2 sec.

5 min.

Summary of Contents for MS-12TE

Page 1: ... human body Suitable for indoor outdoor 1 This sensor is equipped with an AND detection and pulse count system 2 The AND detection system will issue an alarm signal only when detection occurs in both horizontal and downward zones simultaneously 3 The sensor is equipped with many features such as Alarm output control depending on the illuminance of the surrounding area Á Output time delay switch se...

Page 2: ...esn t output signal This sensor operates during detecting time delay time set by a potentiometer It continues to issue alarm as long as it detects objects regardless of set delay time Do not pour water on this unit with a hose as it is designed to be rainproof not waterproof When detection mode is set at AND mode this sensor outputs alarm signal only when both upper and lower sensor detect objects...

Page 3: ...OP VIEW Wall Detection DETECTION MODE OR Fine Adjustment 3 3 3 3 Masking unnecessary zones Variable range Downward zone 10m 33 10m 33 5m 16 5 5m 16 5 0 Detection distance is set by adjusting the angle of downward zone Adjusting range 10 3m to 40 12m 7 ranges Detection distance is set by adjusting the angle of downward zone Adjusting range 10 3m to 40 12m 7 ranges The detection zone of this unit co...

Page 4: ...ment Detection distance can be adjusted within a range from 10 3m to 40 12m by turning the angle of downward zone vertically Refer to the index and slide the adjustment lever up or down Slide it up and the detection distance becomes shorter sliding it down detection distance becomes longer Detection distance depends on how the sensor is installed and how its sensitivity adjustment is set Area mask...

Page 5: ...e can be adjusted between 2sec and to 5min approx Delay time ON OFF ON OFF Factory set ON 1a 1b OFF a N O b N C Factory set Less sensitive prevents false alarms caused by temperature fluctuation More sensitive ON OFF ON OFF Factory set Lights at alarm LED disabled During warm up period light flickers ON OFF AND OR Factory set Alarm signal is issued only when both upper and lower sensors detect obj...

Page 6: ... when two or more sets are connected is the value above divided by number of sets 2 The signal line can be wired to a distance of up to 3 000ft 1 000m with AWG 22 dia 0 65mm telephone wire 3 Wire Insertion Break one outside knockout and its related inside knockout as necessary Pull wire through the insertion holes and connect it to the terminals Break inside knockout pull wire through wiring hole ...

Page 7: ...stment 1 Readjust the protection area setting 2 Improper operation mode setting 2 Readjust operation mode setting 3 Cover face is soiled with dust or water drop 3 Clean the cover with soft cloth 4 Area covered by both upper and lower sensor is too small to be 4 Readjust the sensor angle detected when set at AND mode Only applicable to MS 12FE Activated when no 1 Unstable power voltage 1 Stabilize ...

Page 8: ... to 122ºF 20ºC to 50ºC Mounting position Indoor Outdoor Height 0 8 1 2m Weight 13 7oz 390g 16 5oz 470g Appearance Body AES resin Lens PE resin Accessory Tapping screw 2 Tapping screw 2 Area masking sheet 1 Area masking sheet 2 Optional Wall mount attachment BW 24 Pole attachment BP 22 TAKEX Europe Limited Aviary Court Wade Road Basingstoke HANTS RG24 8PE UK Tel 44 0 1256 475555 Fax 44 0 1256 46626...

Reviews: