1. Precautions on Installation

2. Other Precautions

Install the unit at the height of 2.6’ to 4.0’ from the ground.

Do not install the unit by

an air conditioning exhaust
vent.

Remove all obstructions

(trees, clotheslines, etc.).

Remove all obstacles (including clear glass), which will 
create non detection zone.

Make sure that downward zone will not be affected by sun 
light reflected by water on the road etc.

Operation LED blinks for about 1 min after turning on power.
During this warm up period, the sensor doesn’t make 
detection.

Day light switch allows this unit to issue an alarm signal only 
when the surrounding area is darker than set illuminance. 
In other words, if surrounding area is brighter than set 
illuminance, this sensor doesn’t output signal.

This sensor operates during detecting time + delay time set by 
a potentiometer.
It continues to issue alarm as long as it detects objects 
regardless of set delay time.

Do not pour water on this unit with a hose as it is designed to 
be rainproof, not waterproof.

When detection mode is set at AND mode, this sensor outputs 
alarm signal only when both upper and lower sensor detect 
objects.
In other words, it won’t make detection in the area, which is 
not covered by both upper and lower sensor.
[Only applicable to MS-12FE]

Install the unit in such a direction that people are more

likely to cross the detection zone.

Install the unit horizontally so that its horizontal zone is

parallel to the ground.

2.6’~4.0’ (0.8~1.2m)

Non detection area

Upper sensor coverage
(No detection)

Upper sensor coverage

Lower sensor coverage

Lower sensor coverage
(No detection)

[Detection area]

(This area covered by both

upper and lower sensor)

Summary of Contents for MS-12TE

Page 1: ... human body Suitable for indoor outdoor 1 This sensor is equipped with an AND detection and pulse count system 2 The AND detection system will issue an alarm signal only when detection occurs in both horizontal and downward zones simultaneously 3 The sensor is equipped with many features such as Alarm output control depending on the illuminance of the surrounding area Á Output time delay switch se...

Page 2: ...esn t output signal This sensor operates during detecting time delay time set by a potentiometer It continues to issue alarm as long as it detects objects regardless of set delay time Do not pour water on this unit with a hose as it is designed to be rainproof not waterproof When detection mode is set at AND mode this sensor outputs alarm signal only when both upper and lower sensor detect objects...

Page 3: ...OP VIEW Wall Detection DETECTION MODE OR Fine Adjustment 3 3 3 3 Masking unnecessary zones Variable range Downward zone 10m 33 10m 33 5m 16 5 5m 16 5 0 Detection distance is set by adjusting the angle of downward zone Adjusting range 10 3m to 40 12m 7 ranges Detection distance is set by adjusting the angle of downward zone Adjusting range 10 3m to 40 12m 7 ranges The detection zone of this unit co...

Page 4: ...ment Detection distance can be adjusted within a range from 10 3m to 40 12m by turning the angle of downward zone vertically Refer to the index and slide the adjustment lever up or down Slide it up and the detection distance becomes shorter sliding it down detection distance becomes longer Detection distance depends on how the sensor is installed and how its sensitivity adjustment is set Area mask...

Page 5: ...e can be adjusted between 2sec and to 5min approx Delay time ON OFF ON OFF Factory set ON 1a 1b OFF a N O b N C Factory set Less sensitive prevents false alarms caused by temperature fluctuation More sensitive ON OFF ON OFF Factory set Lights at alarm LED disabled During warm up period light flickers ON OFF AND OR Factory set Alarm signal is issued only when both upper and lower sensors detect obj...

Page 6: ... when two or more sets are connected is the value above divided by number of sets 2 The signal line can be wired to a distance of up to 3 000ft 1 000m with AWG 22 dia 0 65mm telephone wire 3 Wire Insertion Break one outside knockout and its related inside knockout as necessary Pull wire through the insertion holes and connect it to the terminals Break inside knockout pull wire through wiring hole ...

Page 7: ...stment 1 Readjust the protection area setting 2 Improper operation mode setting 2 Readjust operation mode setting 3 Cover face is soiled with dust or water drop 3 Clean the cover with soft cloth 4 Area covered by both upper and lower sensor is too small to be 4 Readjust the sensor angle detected when set at AND mode Only applicable to MS 12FE Activated when no 1 Unstable power voltage 1 Stabilize ...

Page 8: ... to 122ºF 20ºC to 50ºC Mounting position Indoor Outdoor Height 0 8 1 2m Weight 13 7oz 390g 16 5oz 470g Appearance Body AES resin Lens PE resin Accessory Tapping screw 2 Tapping screw 2 Area masking sheet 1 Area masking sheet 2 Optional Wall mount attachment BW 24 Pole attachment BP 22 TAKEX Europe Limited Aviary Court Wade Road Basingstoke HANTS RG24 8PE UK Tel 44 0 1256 475555 Fax 44 0 1256 46626...

Reviews: