55
CONTROLS
2. Stop the engine and open the selector
valve (1) on the machine body.
(The residual pressure is released from
the (b) port line.)
When equipped with accumulator (option):
Refer to page 177 “Accumulator”.
Selector valve
O
: Open ....... When using a hydraulic
breaker (1-way flow)
S
: Closed ..... When using a reversible
attachment (2-way flow)
Change the direction of the hydraulic oil flow
by opening or closing the selector valve on
the machine body.
Accessories
1-way
2-way
1
O
S
J1C0012
External Power Sockets (for EU)
WARNING
Only use applicable electric products with
these sockets.
for Beacon
Use these sockets as an external power
supply. When using these sockets, be
careful not to exceed 12V/10A.
To use, raise the cap (1).
Applicable plug: BOSCH 0352321007
L2C0071
1
1
N0C008