![background image](http://html2.mh-extra.com/html/takeuchi/tb53fr/tb53fr_operators-manual_3347330117.webp)
115
MAINTENANCE
Every 50 Hours
Inspecting the Battery Fluid Level
and Replenishing
DANGER
¡
¡
¡
¡
¡
Do not use the battery when the fluid
level is below the lower level. Doing so
will hasten the deterioration of the
internal portions of the battery and
shorten the battery life, and can also
cause rupturing (or an explosion).
¡
¡
¡
¡
¡
Batteries generate flammable and
explosive gases. Keep arcs, sparks,
flames and lighted tobacco away.
¡
¡
¡
¡
¡
Use dampened cloth to clean the area
of the fluid level lines and check the
fluid level. Note that if this area is
cleaned with a dry cloth, static
electricity could cause ignition or
explosion.
WARNING
¡
¡
¡
¡
¡
Do not fill the battery above the upper
level. Doing so could cause the fluid
to leak, contact and damage the skin,
or cause parts to corrode.
¡
¡
¡
¡
¡
Batteries contain sulfuric acid which
will damage eyes or skin on contact.
• If acid contacts eyes, flush
immediately with clean water and get
prompt medical attention.
• If acid is accidentally swallowed,
drink large quantities of water or milk
and call a physician immediately.
• If acid contacts skin or clothing, wash
off immediately with clean water.
Inspection
IMPORTANT: Check the fluid level of all
cells, even when the fluid level can be
checked by indicator.
1. Loosen the bolts and remove the cover
(1).
2. Remove the angle (2).
3. Pull out the battery and inspect the
indicator (3).
¡
Blue: Good
¡
White: Charging needed
¡
Red: Insufficient battery fluid
4. Inspect the fluid level.
The fluid level should be between the lines
indicating the upper level (H) and lower
level (L). If not, add distilled water up to
line (H).
¡
If the fluid level can not be checked by
fluid level lines.
L4G011
1
2
4
L
H
3
G5G004
Summary of Contents for TB53FR
Page 6: ...4...
Page 8: ...6...
Page 91: ...89 TRANSPORT Loading and Unloading 90 Securing the Machine 91 Cautions on Transporting 92...
Page 140: ...138...
Page 152: ...150...
Page 156: ...154 SPECIFICATIONS Machine Dimensions J1K0011 N L M D Q P J H K C F G A S E B R T U...
Page 158: ...156 SPECIFICATIONS Operating Range J1K0021 D J H K C F G A E B...
Page 160: ...158 MEMO...
Page 168: ...166...
Page 174: ...172 MEMO...
Page 186: ...184...
Page 187: ...185 INDEX...