5-7
MAINTENANCE
LIST OF CONSUMABLES
Periodically replace consumables such as filters and elements according to the table below.
SERVICE DATA
System
Item
Part name
Part No.
When to replace
Hydraulic system
Hydraulic oil
return filter
Cartridge
15510-20310
Every 500 hrs after
the initial 50 hrs.
Air breather (if equipped)
Applicable machine models:
211000997 or later
15520-03000
Every 1000 hrs.
Engine lubrication
system
Engine oil filter
Cartridge
K15841-32432 Every 250 hrs after
the initial 50 hrs.
Fuel system
Fuel filter
Element
KRA211-51280
Every 500 hrs.
Pre-fuel filter (if equipped)
Applicable machine models:
211001351 or later
K12581-43012
Air cleaner system Air cleaner
Primary (Outer)
element
K1G659-11220
Every 1000 hrs. or
after 6 cleanings
(whichever comes
first)
Secondary
(Inner) element
19111-01342
When the primary
element is
replaced.
Summary of Contents for TB210R
Page 1: ......
Page 10: ...0 8...
Page 11: ...1 1 SAFETY...
Page 44: ...1 34 SAFETY SAFETY SIGNS DECALS...
Page 45: ...1 35 SAFETY SAFETY SIGNS DECALS...
Page 46: ...1 36 SAFETY SAFETY SIGNS DECALS...
Page 47: ...1 37 SAFETY SAFETY SIGNS DECALS...
Page 48: ...1 38...
Page 49: ...2 1 CONTROLS...
Page 71: ...3 1 OPERATION...
Page 101: ...4 1 TRANSPORT...
Page 106: ...4 6...
Page 107: ...5 1 MAINTENANCE...
Page 159: ...6 1 TROUBLESHOOTING...
Page 175: ...7 1 SPECIFICATIONS...
Page 177: ...7 3 MEMO...
Page 178: ...7 4 SPECIFICATIONS MACHINE DIMENSIONS MACHINE DIMENSIONS...
Page 180: ...7 6 SPECIFICATIONS MACHINE DIMENSIONS Limited boom swing angle type...
Page 182: ...7 8 SPECIFICATIONS OPERATING RANGES OPERATING RANGES...
Page 184: ...7 10 MEMO...
Page 186: ...7 12 SPECIFICATIONS LIFTING CAPACITIES...
Page 187: ...7 13 SPECIFICATIONS LIFTING CAPACITIES...
Page 188: ...7 14...
Page 189: ...8 1 OPTIONS...
Page 203: ...8 15...