background image

COUNTRY

REGISTERED PLACE OF BUSINESS & ADDRESS

TAKARA BELMONT(U.K.)LTD.

BELMONT HOUSE, ONE ST.ANDREWS WAY, BOW
LONDON E3 3PA, ENGLAND

TAKARA COMPANY EUROPE GmbH

BERNER STRASSE 18, 60437
FRANKFURT/M,GERMANY

TAKARA COMPAGNIE PARIS S.A.R.L.

56 rue des Hautes Pâtures
92009 NANTERRE Cedex France

GBR

Importer in UK

Importeur in Deutschland

DEU

FRA

Importateur en France

IMPORTER  INFORMATION 

TAKARA BELMONT ITALY S.R.L.

Via Marino Mazzacurati No.4/1, 42019 Scandiano RE, Italy

Importatore in Italia

ITA

TAKARA COMPANY EUROPE GmbH

Berner Strasse 18, 60437 
Frankfurt am Main, Germany

TAKARA BELMONT CORPORATION

2-1-1, Higashishinsaibashi,Chuo-ku,Osaka, 542-0083, Japan

TAKARA BELMONT(U.K.)LTD.

BELMONT HOUSE, ONE ST.ANDREWS WAY, BOW 
LONDON E3 3PA, ENGLAND

EU  Authorised representative

UK  Authorised representative

EU  Declaration of Conformity

We hereby declare that the product listed below complies with the essential requirements of the

EMC (electromagnetic compatibility) Directive : 2014/30/EU,Low Voltage Directive : 2014/35/EU,

Machinery Directive : 2006/42/EC and RoHS Directive : 2011/65/EU based on category 11 of Annex I.

Product : BEAUTY SHAMPOO UNIT

Model     : YUME(YUME, K-YUME)

The product has been designed and manufactured in accordance with the European standards as the

listed in the Declaration of Conformity.

UK  DECLARATION OF CONFORMITY 

We declare under sole responsibility that the device that is covered by the present declaration is in 

conformity with the following regulations and, if applicable, with any other relevant UK legislation 

that provides for the issuing of an UK declaration of conformity.

Product : BEAUTY SHAMPOO UNIT

Model   : YUME(YUME, K-YUME)

Regulations this product conforms to:

The Electrical Equipment (Safety) Regulations 2016, S.I. 2016/110               

The Electromagnetic Compatibility Regulations 2016, S.I. 2016/1091                

The Supply of Machinery (Safety) Regulations 2008, S.I. 2008/1597               

The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment 

Regulations 2012, S.I. 2012/3032 based on category 11 of PART 1, SCHEDULE I  

Summary of Contents for YUME

Page 1: ...erstood before use Using this product before reading this operating instructions may result in an accident This product is an industrial shampoo unit designed for barbers and hair salons Only use this...

Page 2: ...ion and Specifications 2 3 Overall View and Major Components 3 4 Accessories 4 5 Preparation 4 6 Operating Instruction 6 7 Maintenance 9 8 Troubleshooting 12 9 Parts Replaced on a Regular Basis 13 10...

Page 3: ...1 Locations of Warning Labels 1...

Page 4: ...Requirements AC 240V 50 60 Hz 2 3 2 3A Electrical Requirements AC 230V 50 60 Hz 2 1 2 4A CE Spec Usage Environment Operational Temperature 10 40 Water and Hot Water 0 1 0 4Mpa 1 4kgf cm2 Supply Press...

Page 5: ...Auto Return Backrest Raising Backrest Reclining Seat Lowering Seat Lifting Auto Return Backrest Reclining Backrest Raising Thermostatic control knob Body cover EX YM L left side foot control EX YM R...

Page 6: ...Mohair Tape 1 5 Preparation Head Pillow 5 1 Attach the Neck Cushion 1 Attach the neck cushion on metal fittings as shown in figure 2 Both side snap button of the neck cushion is fixed on a fixed pin 5...

Page 7: ...the shower head holder and the cover Align groove in the cover and protrusion of the holder until they snap into place Protrusion Sponge Cover Sponge holder Shower head holder Do not remove the cover...

Page 8: ...ol A Seat Lifting Keep depressing Seat lifting switch until the seat is lifted up to the desired position B Seat Lowering Keep depressing Seat lowering switch until the seat is lowered to the desired...

Page 9: ...backrest to the desired preset position by manual control B Turn off main switch C While depressing Preset switch turn on main switch D Keep depressing Preset switch until buzzer sounds then release i...

Page 10: ...he tap to anticlockwise B Adjust the water temperature with thermostatic control knob C Press stop button on the thermostatic control knob to release lock for hot water then turn clockwise Stop Stop B...

Page 11: ...sponges containing abrasives etc Thinner Gasoline Waxes Containing abrasives Chemicals 7 3 Use dry and soft cloth to clean upholstery plastics plated and painted surface Dump cloth with neutral deter...

Page 12: ...ery day After cleaning the sponge put it in the hose and put it back on the cover Remove the shower head The figure on the right Remove the cover from the shower hose 1 2 Install a new cover 3 Shower...

Page 13: ...r hot water stop valves and remove strainer by flat head screw driver and wipe off the water by cloth E After cleaning the strainer put it back and tighten up F Wipe water off and remove cloth G Turn...

Page 14: ...ower plug is properly plugged into the outlet If you have a breaker box check for tripped breakers Main Switch ON Fuse Box or Breaker No Water Hot Water Make sure that the water hot water stop valve h...

Page 15: ...contamination of city water or public health problems Water hot water supply hose Replace every three years For the water hot water supply hose there is a possibility that cracks due to deterioration...

Page 16: ...EMC electromagnetic compatibility Directive 2014 30 EU Low Voltage Directive 2014 35 EU Machinery Directive 2006 42 EC and RoHS Directive 2011 65 EU based on category 11 of Annex I Product BEAUTY SHAM...