5 Disconnected/damaged O.H.C.F.
(Refer to section 10-13)
C2
Visual inspection:connection/breakage of wires.
Normal: 1
Ω
or less between blue & blue
6 Check if hi-limit switch is properly functioning.
7
C1
Normal: 1
Ω
or less between blue & blue
Checkpoint
1 Outlet thermistor fault
(Refer to section 10-11)
Check voltage/resistance between black & black (#12).
Refer to Section 8 for proper range of values.
Checkpoint
1 Inlet thermistor fault
(Refer to section 10-11)
Check voltage/resistance between black & black (#42).
Refer to Section 8 for proper range of values.
Checkpoint
1 Mixing thermistor fault
(Refer to section 10-11)
Check voltage/resistance between black & black (#113).
Refer to Section 8 for proper range of values.
Checkpoint
1 AFR rod fault
(Refer to section 10-6)
I
Visual inspection:connection/breakage of wires and/or soot buildup.
391
331
321
Visual inspection: connection/breakage of wires.
121
Error code is
shown after
three failed
attempts at
ignition
Error Code
Malfunction description
Cancellation method
Disconnected/damaged hi-limit switch.
(Refer to section 10-12)
Disconnected/short-circuited outlet
thermistor
Turn off the power or water
supply
Diagnosis
E2
Visual inspection: connection/breakage of wires and/or debris
on thermistor.
311
Error Code
Malfunction description
Cancellation method
Disconnected/short-circuited inlet thermistor Turn off the power or water
supply
Diagnosis
E3
Visual inspection: connection/breakage of wires and/or debris
on thermistor.
Error Code
Malfunction description
Cancellation method
Disconnected/short-circuited mixing
thermistor
Turn off the power or water
supply
Diagnosis
E1
Visual inspection: connection/breakage of wires and/or debris
on thermistor.
Error Code
Malfunction description
Cancellation method
Disconnected AFR rod
Turn off the power or water
supply
Diagnosis
Error Code
Malfunction description
Cancellation method