T-K3 Service Manual
Ver. 1.05
23
CONFIDENTIAL
10-11. Thermistors
T-K3 Part #
#406 (Inlet)
#407 (Outlet)
#408 (Mixing)
Takagi Part #
EKK38 (Inlet)
EKK2T (Outlet)
EKK1A (Mixing)
Checkpoint
E1 (Mixing)
E2 (Outlet)
E3 (Inlet)
Function
Failure event
Effects on the T-K3
if thermistor fails
Error codes when
thermistors fails.
311 (Outlet)
321 (Inlet)
331 (Mixing)
Diagnostic
Measure cold/hot water temperatures in the T-K3.
Unable to properly measure water temperatures within the T-K3.
1. Visual inspection: connection/breakage of wires and/or debris on thermistor
2. Check voltages and resistance; proper range of values shown below.
Color/Number of
wires
If the thermistors fail open or short, error code appears before starting operation. If
resistance values are just off, T-K3 will have temperature fluctuations in hot water.
Inlet Black(42)-Black
Outlet Black(12)-Black
Mixing Black(113)-Black
68
˚
F (20
℃
)
9.0~13K
Ω
122
˚
F (50
℃
)
3.3~4.4K
Ω
176
˚
F (80
℃
)
1.4~1.8K
Ω
(see table below for more resistance values)
0.00
5.00
10.00
15.00
20.00
25.00
20
40
60
80
100
120
140
160
180
200
220
Temperature / ºF
R
esi
si
ta
n
ce
/ k
Ω
(Mixing thermistor)
(Outlet thermistor)
(Inlet thermistor)
Blue
Black
Black
Insulating
Resistance values of thermistors as a function of