41
Page
Troubleshooting
Owner's Guide
Unit #
Error code
Error code
ERROR CODES
-General-
•
The units have self-diagnostic functions for safety and convenience when troubleshooting.
•
If there is a problem with the installation or the unit, the error code will be displayed on the
temperature controller and remote controller.
•
Consult the table on the following pages for the description of each error code.
-Single unit installation-
Example: If your unit has the “321” error code (which signifies an inlet thermistor failure)
•
Indicator on the built-in controller and/or remote controller:
“321” will be displayed on the screen.
•
Green LED on the computer board:
The green LED on the computer board will indicate this code with
two flashes every 1/2 second. The pattern will repeat with a three second delay between patterns.
-Easy-Link System-
(For the 510C model only)
Error codes will be displayed differently with units installed within an Easy-Link System, not only to show
what the error code is, but to also indicate which unit within the system has the error code. Below is a
sample of how the error code of "321" is displayed in an Easy-Link System.
Example: If Unit #2 has the “321” error code (inlet thermistor failure)
•
Indicator on the built-in controller
and/or remote controller of Parent unit:
“321” and "2" will intermittently flash on
the display.
•
Unit #2:
"321" will intermittently flash on the display.
The green LED on the computer board will
flash twice, just like in the single unit example.
•
Unit #3 and #4:
These units will not display anything,
as the error code does not pertain to them.
Green LED
110C and 310C
models
Error code on the computer board
510C model
Green LED
Error code indicator on
the built-in controller
Error code indicator on
the remote controller
Indicated by 1/2-second flashes on the Green LED.
100209924
(TM-RE42)
Unit #1
PARENT
Unit #2
CHILD
Unit #4
CHILD
Unit #3
CHILD