background image

 

 

 

- 15 - 

3.4.1 Switching of receiver (audio) 

Switching of the internal or external receiver is set by the following procedure. 
Press              key.    Then  the  receiver  switching 
mode is set and message on the right appears.  
The displayed number 1 is for internal receiver, 2 
is for external receiver.  Pressing the       key 
after setting a        key, completes the setting. 

3.4.2 Setting of timer reception 

This unit has 16 booking functions and each timer is set as follows. 
Press       key.  Then the timer reception 
setting mode is set and the message is shown on 
the right.  The displayed number correspond to 
the following entries respectively. 

 1 

Release 

 2 

Setting 

 

3  :  Re-calling (readout of the booking data)   

 4 

Entry 

booking 

(1) Release 

Press              key.    Then  the  message  is  shown 
on the right.  Pressing the       key releases 
the timer mode 
 
 

(2) Setting 

Press       key.  Then the message is shown 
on the right.     
Select  booking  number(s),  0~F,  by pressing
 

 

key.  The display shown on the 

right is an example when selecting booking 
number “0”. 
Then, press       key to fix the selection 
Plural selection of the booking numbers are 
acceptable.  The display shown on the right is 
an example when select and fix the booking 
number “0”, “1”, “2” and “3”.   
Press the       key to complete the setting. 

 

  AF 

IN : INT 

 1-INT  2-EXT 

 E  

 

0

 1  

  TIMER    RCV : 1-OFF 

 2-ON  3-RCL   4-STR 

 TIMER    RCV : OFF 

 PUSH  E   KEY 

 SET  REG  No.  0-F 

 PUSH 

/

▽ &

 &E KEY 

 TIMER  RCV  NO.: 0 

   

 2 

 1  

 E  

 2  

 E  

 TIMER  RCV  NO.: 3 

 0123 

 

 

 

Summary of Contents for TF-711

Page 1: ...USERʼS MANUAL OF SYNTHESIZED THERMAL WEATHER FACSIMILE RECEIVER T F 7 1 1 No MPP0446 May 2003 Version No 1 3 ...

Page 2: ... circuit Do not heat it or put it into fire SAFETY INSTRUCTIONS WARNING Personal injury or damage to property may occur when handled improperly Use the power supply as defined in the specification Select a position to install the main unit Avoid rain or water splash direct sunshine strong vibration or high temperature Keep a separation larger than 1 1 m from a magnetic compass or 0 9 m from a stee...

Page 3: ... Selection of reception mode 13 3 3 7 Timer release and release of keylock in the timer mode 14 3 4 Description of setting mode 3 4 1 Switching of receiver audio 15 3 4 2 Setting of timer reception 15 3 4 3 Sleep timer setting 17 3 4 4 Registration of new frequency 17 3 4 5 Time setting 18 3 4 6 Setting of ISB frequency 19 3 4 7 RAM clearance function 20 3 4 8 Attention at the time of operation 20...

Page 4: ...ead IOC Index of cooperation 576 and 288 Recording speed 60 90 120 scans per minute Gradation 9 tones white 7 gray levels and black Recording paper Thermal paper 257 mm X 60 m Line density 8 dots mm total number of dots 2048 1 3 Automatic Control Start stop Automatic start or stop by timer program and or WMO standard remote control signal or manual Recording rate Automatic selection of recording r...

Page 5: ...olid and plane wall with 4 pcs of screws and washers Caution A print may become blurred if the installation place is uneven In that case put some washers or suitable attachment to adjust the flatness as following figure Setscrew for cabinet Setscrew For cabinet Washer TF 711 main unit ...

Page 6: ...socket 1 minus White wire Connector socket 2 plus 2 2 2 AC power supply cable Use AC power supply cable when the main unit is AC power supply AC 100 115 200 230 V type The voltage specified at the time of an order is set When you change voltage please change a setup of the power supply part of the main unit White 2 1 16 P2F Looking from receptacle side DC Power cable VCTF 0 75 2 1 Black White 2 1 ...

Page 7: ... single core 0 4 1 0mmØ or standard twist core 0 3mm2 0 7mm2 2 4 Grounding A GND terminal is on the rear panel of the main unit Be sure to ground the main unit using attached earth wire 3m KIV wire 50 0 45 with copper tube terminal Insert a connection wire to a hole while pressing the push knob Push knob Wire hole Connection wire Press a push knob by a screwdriver Terminal board Peel off vinyl she...

Page 8: ...ecome worse when using one antenna for other receivers and or transmitters through multi coupler In that case please use other antenna or install exclusive antenna Be sure to connect BK especially for following case in order to avoid from burning trouble of antenna coil receiver circuit A In case of using same antenna which is used for a transmitter B When a transmitting antenna is located near to...

Page 9: ... Fig 1 2 Set the roll paper to the holder by pressing a paper guide to left side Ref Fig 2 Note A paper detection sensor is at the middle left of the holder and is weak against a shock Therefore be careful to do not damage it when setting the roll paper 3 Pull out the end of paper upwards from under the rubber roller Ref Fig 3 Fig 1 Fig 2 Fig 3 ...

Page 10: ...t that time place the end of paper above the front cover Ref Fig 6 Fig 6 5 Return the paper cutting plate to the original position Fig 5 4 Pull down ahead the paper feed lever pulling the end of paper a little ahead Ref Fig 4 Fig 4 ...

Page 11: ...y and next a key Be sure to follow instruction of the indicator in selecting a mode To cancel a setting press the key to reset to the initial display of selection mode Then press a key to reset or the key to set the standard operation mode PRG PRG C N 0 9 N 0 9 1 1 key 2 2 key 3 key 3 4 4 key 5 5 key 6 6 key 9 key 9 PRG Switch the receiver internal or external Set timer reception Set sleep timer S...

Page 12: ...ess of the key shifts 2 5 of the paper width Down key Channel down in the channel mode or frequency down in the frequency mode Reverse key REV For reversal of black white of the recording or dot key Decimal point in setting time or frequency A press of the key alternates the REV Frequency key For selection of frequency mode from channel mode and for shift to frequency setting in the frequency mode...

Page 13: ...t mode Record key To start and stop recording In the non recording mode a press of key sets automatic phasing mode and recording starts when phasing is completed In the automatic phasing a press of key stops the automatic phasing and starts recording A press of key while recording stops recording key Time display clock function Number key To enter number or mode Entry key To acknowledge setting E ...

Page 14: ...el number Selection of a channel is possible by pressing key first and next three keys When a station is chosen with two keys and the key is pressed asterisk mark appears in the 3rd figure and the most sensitive frequency of that station is selected automatically 3 3 2 Fine adjustment of frequency and selection of a desired frequency In the frequency display mode fine adjustment of the frequency w...

Page 15: ...nal is received In the absence of auto stop signal or to stop halfway press key 3 3 4 Manual phasing In manual recording mode or when the phasing is not completed in the proper position by auto phasing be sure to adjust the phase using the key The phase signal shifts by 2 5 of the paper width or about 6 4mm per keying 3 3 5 Synchronization When a recorded picture phase signal etc drifts to left or...

Page 16: ...on the right appears Press key to select correct speed b Change of IOC Press key then the display on the right appears Press key to select correct IOC 2 Reverse mode When recorded picture is reversed white black follow the procedure below Press key then the display on the right appears Press key to select mode 3 Time display A built in clock is provided The present time is displayed by pressing ke...

Page 17: ...sage on the right appears Fixing with the key releases the keylock even though in the timer operation mode each key function is revised and all operations are possible To release the timer mode in such a case refer to 1 4 2 When the keylock off is displayed it is possible to clear the keylock off with the key 3 4 Description of setting mode Shift to a set mode is made by pressing the key When the ...

Page 18: ...ollowing entries respectively 1 Release 2 Setting 3 Re calling readout of the booking data 4 Entry booking 1 Release Press key Then the message is shown on the right Pressing the key releases the timer mode 2 Setting Press key Then the message is shown on the right Select booking number s 0 F by pressing key The display shown on the right is an example when selecting booking number 0 Then press ke...

Page 19: ...ey Further set a day of the week with key and fix it with the key Then set start and end time with keys from 00 00 to 23 59 After setting is competed fix it with the key To change the time while setting press the key to reset the time After fix with the key the setting is displayed as shown on the right The message on the right is for setting Channel No 000 at JMH 3MHz booking No 1 starting Monday...

Page 20: ... 4 Registration of new frequency Registration of a new frequency 450 724 or re writing of an existent frequency CH000 443 can be made in the following procedure Press the key and the frequency registration mode is set Then message shown on the right appears Enter a channel number with three keys Right example is for channel 000 To change the entered number use the key Then enter a call sign with t...

Page 21: ... 3 4 5 Time setting Clock time can be set by the following procedure Pressing the key sets the time setting mode and message shown on the right appears Set month with key and fix it with key The message on the right shows entering April Next enter date with 2 figures by the key and fix it with the key e g April 10th Then enter day of the week with key and fix it with the key Message shown on the r...

Page 22: ...following 1 Release 2 Setting 3 Shift quantity entry 1 Release Press key and fix with the key to release the mode 2 Setting Press key and fix with the key then a displayed amount of frequency is shifted Be careful as a frequency shift is set in all channels When the power is turned on the shift frequency for all channels is indicated when ISB has been set 3 Shift quantity entry Press key Then use ...

Page 23: ... is needed to clear the RAM data Be careful since all the data in the RAM will be initialized deleting the data of registered frequencies etc when this procedure is performed Pressing key sets the RAM clear mode and pressing key clears the RAM data To stop this procedure press the key or the key 3 4 8 Attention at the time of operation Be careful of the following thing when operation PRG 9 E C CAU...

Page 24: ...stable within a range of 2kHz or more by means of the beat knob set the frequency dial so as to maximize the deflection of the receiver s S meter and adjust the beat knob so that the center LED of the tuning indicator of the unit is lit When a signal from station with ISB communication from a U S Navy station e g Guam Pearl Harbor or San Francisco is received sometimes an adjustment of the frequen...

Page 25: ...n BK board inside the unit attached to the terminal board Turn the power switch OFF and ON again after connection and S2 switch ON The channel as which D is indicated on the lower right of the display shows that the signal comes through a decoder Even if D is not displayed select DECORDER ON at registration of new frequency with reference to 1 4 4 to receive a signal through a decoder ...

Page 26: ...PCA Please be careful about polarity when exchanging it 4 2 Lubrication and Cleaning 1 Lubrication Lubricate a paper sending gear with 1 2 drops of lubricating oil at every 2 3 months 2 Cleaning Clean the thermal head with attached cotton cleaner at every month When garbage has adhered to the thermal head soak a little ethyl alcohol on cloth and wipe it off Don t use other than ethyl alcohol ...

Page 27: ...equencies of facsimile transmitting stations Stations and frequencies are shown in the map and table respectively This table is reference data and is subject to change without previous notice JMH JMJ JJC JFC HLL BAF BDF BMF NPN ZKLF AXI HSW 5YE 6VU PWZ NMF CFH AOK DDK SUU YMA GYA GFE GFA DDH IMB ATA OXT VFF NMC KVM CKN NOJ AXM Area map of existing stations ...

Page 28: ... JFC JAPAN 4274 0 031 JFC JAPAN 6414 5 032 JFC JAPAN 8658 0 033 JFC JAPAN 13074 0 034 JFC JAPAN 16907 5 CHANNEL NO CALL SIGN STATION FREQUENCY kHz 040 HLL SEOUL 5857 5 041 HLL SEOUL 7433 5 042 HLL SEOUL 9165 0 050 BAF BEIJING 5526 4 051 BAF BEIJING 8122 0 052 BAF BEIJING 10117 0 053 BAF BEIJING 14547 4 054 BAF BEIJING 16025 0 055 BAF BEIJING 18237 0 060 BDF SHANGHAI 3241 0 061 BDF SHANGHAI 5100 0 ...

Page 29: ... DIEGO GRACIA 7580 0 151 NKW DIEGO GRACIA 12804 0 152 NKW DIEGO GRACIA 20300 0 CHANNEL NO CALL SIGN STATION FREQUENCY kHz 160 5YE NAIROBI 7464 4 161 5YE NAIROBI 9045 0 162 5YE NAIROBI 12315 0 163 5YE NAIROBI 16186 9 164 5YE NAIROBI 17445 6 165 5YE NAIROBI 22867 0 170 FZS SAINT DENIS 8176 0 171 FZS SAINT DENIS 16335 0 180 ZSJ PRETORIA 4014 0 181 ZSJ PRETORIA 7508 0 182 ZSJ PRETORIA 13538 0 183 ZSJ ...

Page 30: ...A DONU 7630 0 303 ROO ROSTOV NA DONU 9100 0 CHANNEL NO CALL SIGN STATION FREQUENCY kHz 310 RIS TBILISE 3745 0 311 RDK TBILISE 7495 0 320 RBV TASHKENT 3690 0 321 RPJ TASHKENT 4365 0 322 RBV TASHKENT 5890 0 323 RBX TASHKENT 7570 0 324 RCH TASHKENT 9340 0 325 RBV TASHKENT 14982 5 330 RBX TASHKENT 3280 0 331 RBX TASHKENT 5285 0 332 RIJ TASHKENT 8083 0 333 ROM TASHKENT 13947 0 340 RBW MURMANSK 5336 0 3...

Page 31: ...ISO 8677 0 402 CBV VALPARAISO 17146 4 410 NMC SAN FRANCISCO 4346 0 411 NMC SAN FRANCISCO 8682 0 412 NMC SAN FRANCISCO 12730 0 413 NMC SAN FRANCISCO 17151 2 414 NMC SAN FRANCISCO 22527 0 420 CKN VANCOUVER 2754 5 421 CKN VANCOUVER 4268 0 422 CKN VANCOUVER 6456 0 423 CKN VANCOUVER 12753 0 430 NOJ KODIAK 2054 0 431 NOJ KODIAK 4298 0 432 NOJ KODIAK 8459 0 CHANNEL NO CALL SIGN STATION FREQUENCY kHz 440 ...

Page 32: ...External receiver DECODER AF IN AF OUT AF OUT TFM 01 Antenna coupler Option 2m whip antenna M207 P 7C 2V M205 P 5C 2V 7C 2V or 5C 2V M205 P M207 P CAUTION 1 Turn ON the switch S1 on the PCA BK inside the TF 711 main unit when the antenna coupler TFM 01 is used 2 Turn ON the switch S2 on the PCA BK when a decoder is connected Layout diagram AC power supply unit ...

Page 33: ...Base Cabinet Outside view ...

Page 34: ...lease contact to a dealer where you purchased this equipment When the dealer s contact address is uncertain please contact to following address 2 11 18 Higashi Kojiya Ota ku Tokyo 144 0033 JAPAN Overseas Trading Dept TEL 81 3 5735 1247 FAX 81 3 5735 1683 ...

Reviews: