Task 30 —
Repair VCO
If either or both the maximum and minimum frequencies are incorrect, the
VCO circuitry is faulty.
1.
Remove the
VCO
BOT
can.
2.
Check the VCO. The circuitry is based on Q5000
(see
3.
If a fault is found, repair it and go to
. If no fault is found, go
to
4.
Repeat
and
to measure the maximum VCO
frequency.
5.
Repeat
and
to measure the minimum VCO
frequency.
6.
If the frequencies are now correct, resolder R542 in position
(see
), and go to
. If they are
7.
Resolder R542 in position (see
). Replace the main-
board assembly and go to