45
FY operation manual
Notes
1. ANL2 & ANH2 is the current signal calibration parameters. It has been calibrated before leaving the factory.
do not change these two parameters value.
2. The user only needs to set HBAC & HBOP, the rest of the parameters will be set & calibrated at the factory.
3. CT has two specifications: SC 80-T & SC 100-T. Please check heater wire diameter and specify required CT.
CT Specifications
Item
Specifications
Model number
SC 80-T
SC 100-T
Max. continuous current
80A
100A
Accuracy
3%
5%
Aperture
5.9mm
12.6mm
Dieiectric Withstanding Voltage(Hi-pot)
2500Vrms / 1 minute
4000Vrms / 1 minute
Vibration resistance
50 HZ, 98 m/s
2
Weight
Approx. 12 g
Approx. 30 g
Dimensions (UNIT
:
mm)
SC 80-T
SC 100-T