TM
A
1 controller > RS232 settings
|
11
This feature can be used to ‘daisy-chain’ products using RS232 control: It allows data
received on the RS232 input to be relayed to the output (
Input -> Output Only
), vice versa
(
Output -> Input Only
) or between both (
Input <-> Output
). You can also switch relaying
completely off (
Never
).
Relay RS232 Data
Relay Received RC5->IR TX
Relay Received RC5->RS232
Activate this feature if you want to relay RC5 infra red commands, received via the AV32R
Dual Processor’s IR receiver or TAGtronic Bus, to the TMA1’s
IR-TX
output.
You can either connect an IR transmitter to the IR-TX output or connect it directly to a
suitable IR distribution system.
Activate this feature if you want to relay RC5 infra red commands, received via the
AV32R Dual Processor’s IR receiver or TAGtronic Bus, to the RS232 output, RS232 input
or both using the TAG McLaren RS232 Message Protocol.
The Protocol is available from
www.tagmclaren.com
or